メインコンテンツまでスキップ

NetApp_Insight_2020.png 

過熱後に ATTO FibreBridge に到達できません

Views:
7
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

に適用されます

ATTO 6500N
ATTO 7500N
ATTO 7600N
MetroCluster
の過熱
ログ・メッセージログ・メッセージ
 1D0AA8 00:36:43 WARN Temperature Critical Level reached at 71 C
 1D0AA9 00:36:45 CRIT Temperature (71 C) out-of-range (0, 70 C). Going offline.

問題

ATTO ブリッジが削除済みとして報告され、次のようなエラーメッセージが報告されます。
Sat Feb  4 16:06:38 CET [netapp01:bridge.removed:info]: FC-to-SAS bridge sw2:5.125L0 [ATTO     FibreBridge6500N 1.11] S/N [FB6500N123456] was removed.

 

 

 

 

CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support