問題

  • イベントログで呼び出されたアダプタを介してすべてのノードで1つのATTOブリッジへのパスが欠落しています。

[Node-102: isp2400_timeout_0: fci.device.quiesce:debug]: Adapter 1d encountered a command timeout on Unknown device Switch1:10.126 (0x00080a00) LUN 0 cdb 0x12 retry: 0 Quiescing the device.
[Node-102: isp2400_asyncd_0: fci.device.login.status:debug]: A login delay has occurred between Fibre Channel adapter 1d and unknown device Switch1:10.126 (0x00080a00), with error subcode 0x703.
[Node-101: isp2400_timeout_0: fci.device.login.failure:error]: A login failure has occurred between Fibre Channel adapter 1d and unknown device Switch1:10.126 (0x00080a00), with error subcode 0x703.
[Node-101: svc_queue_thread: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED

  • すべてのノードが「クアッドパスHA」構成から「マルチパスHA」構成に移行します。

[Node-101: dsa_disc: shelf.config.tompha:info]: System has transitioned to multi-path HA attached storage

  • 該当するATTOブリッジのFCポートで複数のエラーが報告されます。

get FCPortErrors all

; Fibre Channel Error Counts 
; Port | Link Failures | Sync Loss | Signal Loss | Invalid Tx | Invalid CRC
;==========================================================================
  1          1       3        0       0        0
  2        1957   922594816        0      216     14382

  • 欠落しているATTOブリッジに接続されているスイッチポートでもエラーが発生しています。

porterrshow     :
      frames    enc   crc   crc   too   too   bad   enc  disc link  loss   loss   frjt   fbsy  c3timeout  pcs   uncor
    tx    rx    in   err   g_eof  shrt   long   eof    out  c3   fail   sync   sig          tx  rx    err   err
  9:   3.0g   4.2g   0    0    0    0    0    0    0    1    0    0    0    0    0    0    1    0    0
 10:   1.9g   4.1g   0    2   1    0    1    0    0   892    4   0    4    0    0   892    0    0    0

  • スイッチポートのSFPの送信電力(Tx)が 想定範囲よりも低い

Switch> sfpshow -all

=============
Port 10:
=============

Current:    7.508   mAmps
Voltage:    3304.2  mVolts
RX Power:   -1.5   dBm (706.9uW)
TX Power:   -5.2   dBm (302.0 uW)

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.