メインコンテンツまでスキップ
NetApp Response to Russia-Ukraine Cyber Threat
In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

MetroCluster の誤ったプールと所有者にディスクが自動割り当てされている

Views:
33
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

に適用されます

  • MetroCluster 

問題

新たに交換されたドライブが誤ったプールと所有者に自動割り当てられました 

 Wed Apr 08 09:17:46 UTC [nodeA: dmgr_thread: raid.disk.inserted:info]: Disk 3b.125L517 Shelf 11 Bay 16 [NETAPP X438_S1633400AMD NA01] S/N [S20XXXX] UID [5002538A:758137E0:00000000:00000000:00000000:00000000] has been inserted into the system Wed Apr 08 09:17:46 UTC [nodeA: config_check: config.BadPoolAssign:error]: Disk 1.11.16 is in Pool0 and other disks on this loop/domain are in Pool1. Disks/interfaces need to be in separate pools for SyncMirror. 

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support