問題

ONTAP からアラートが報告されています

Cluster ::> system health alert show
Node: Node1
Resource: fcvi_device_3
Severity: Major
Indication Time: x
Suppress: false
Acknowledge: false
Probable Cause: Physical link on port 5a is offline.
Possible Effect: DR protection of NVRAM mirror might be compromised.
Corrective Actions:
1. Ensure that the FC-VI link has not been tampered with.
2. Verify that the physical status of the FC-VI adapter is "Up" by using the command "metrocluster interconnect adapter show".
3. If the configuration includes fabric switches,
ensure that they are properly cabled and configured.

Cluster::> metrocluster interconnect adapter show -node node1 -adapter fcvi_device_1 -instance

Adapter Name: fcvi_device_1
Adapter Type: FC-VI
Link Status: Down

 
イベントログで次の情報が報告されています
 
[fcvi.update.link.state:notice]: FC-VI adapter: Physical link is down on port 5a.
[fcvi.qlgc.receive.error:error]: FC-VI adapter: Received bad frame on port 5a. Mailbox-1 = 4105, Mailbox-2 = 69. Resetting the port.
 

 