問題

  • SCW では、 Windows アプリケーションイベントログの次の例に示すような重大なエラーが報告されます。

例1:

Critical SDW PID=[<PID>] TID=[<TID>] The running command stopped because the preference variable "ErrorActionPreference" or common parameter is set to Stop: entry doesn't exist 
  at System.Management.Automation.Internal.PipelineProcessor.SynchronousExecuteEnumerate(Object input, Hashtable errorResults, Boolean enumerate)
  at System.Management.Automation.Runspaces.LocalPipeline.InvokeHelper()
  at System.Management.Automation.Runspaces.LocalPipeline.InvokeThreadProc()

例2

Critical SDW PID=[<PID>] TID=[<TID>] The running command stopped because the preference variable "ErrorActionPreference" or common parameter is set to Stop: entry doesn't exist 
 at System.Management.Automation.Runspaces.PipelineBase.Invoke(IEnumerable input)
 at SnapDrive.Nsf.Common.PowerShell.PSHelper.RunCommand(Command command,
IEnumerable 入力)

例3

Critical SDW PID=[<PID>] TID=[<TID>] The running command stopped because the preference variable ""ErrorActionPreference"" or common parameter is set to Stop: 
===================================================================================
| This cmdlet must be directed to a data vserver.  You are currently connected   |
| to the cluster admin vserver.  See the Toolkit web docs (Show-NcHelp) or online |
| help (Get-Help Connect-NcController -Examples) to learn more about directing   |
| Toolkit cmdlets to a cluster or data vserver as required by Data ONTAP.      |
===================================================================================

  at System.Management.Automation.Runspaces.PipelineBase.Invoke(IEnumerable input)
  at SnapDrive.Nsf.Common.PowerShell.PSHelper.RunCommand(Command command, IEnumerable input)

 

  • SCWDebug.logの例に示すような出力がに表示されます。

例1:

Critical SDW PID=[<PID>] TID=[<TID>] The running command stopped because the preference variable "ErrorActionPreference" or common parameter is set to Stop: entry doesn't exist   at System.Management.Automation.Internal.PipelineProcessor.SynchronousExecuteEnumerate(Object input, Hashtable errorResults, Boolean enumerate)
   at System.Management.Automation.Runspaces.LocalPipeline.InvokeHelper()
   at System.Management.Automation.Runspaces.LocalPipeline.InvokeThreadProc()

Verbose SDW PID=[<PID>] TID=[<TID>] ex.Message : The running command stopped because the preference variable "ErrorActionPreference" or common parameter is set to Stop: entry doesn't exist
Verbose SDW PID=[<PID>] TID=[<TID>] No retry condition match found or max retry reached. Throwing error The running command stopped because the preference variable "ErrorActionPreference" or common parameter is set to Stop: entry doesn't exist
Verbose SDW PID=[<PID>] TID=[<TID>] --PSHelper::RunCommand
Error SDW PID=[<PID>] TID=[<TID>] Failed to get FCP target node name for StorageSystem: svm1.demo.netapp.com
 entry doesn't exist
Verbose SDW PID=[<PID>] TID=[<TID>] ++StorageConnectionPool::CleanUpIfStale
Verbose SDW PID=[<PID>] TID=[<TID>] --TargetInfoCacheHelper::GetTargetInfo
Verbose SDW PID=[<PID>] TID=[<TID>] ++TargetInfoCache::ShouldGetTargetInfo
Verbose SDW PID=[<PID>] TID=[<TID>] --TargetInfoCache::ShouldGetTargetInfo
Error SDW PID=[<PID>] TID=[<TID>] FCP target information is null/empty

例2

Critical SDW PID=[<PID>] TID=[<TID>] The running command stopped because the preference variable "ErrorActionPreference" or common parameter is set to Stop: entry doesn't exist 
   at System.Management.Automation.Runspaces.PipelineBase.Invoke(IEnumerable input)
   at SnapDrive.Nsf.Common.PowerShell.PSHelper.RunCommand(Command command, IEnumerable input)

Verbose SDW PID=[<PID>] TID=[<TID>] ex.Message : The running command stopped because the preference variable "ErrorActionPreference" or common parameter is set to Stop: entry doesn't exist 
Verbose SDW PID=[<PID>] TID=[<TID>] No retry condition match found or max retry reached. Throwing error The running command stopped because the preference variable "ErrorActionPreference" or common parameter is set to Stop: entry doesn't exist 
Verbose SDW PID=[<PID>] TID=[<TID>] --PSHelper::RunCommand
Error SDW PID=[<PID>] TID=[<TID>] Failed to get FCP target node name for StorageSystem: <STORAGESYSTEM>
The running command stopped because the preference variable "ErrorActionPreference" or common parameter is set to Stop: entry doesn't exist
Verbose SDW PID=[<PID>] TID=[<TID>] ++StorageConnectionPool::CleanUpIfStale
Verbose SDW PID=[<PID>] TID=[<TID>] --TargetInfoCacheHelper::GetTargetInfo
Verbose SDW PID=[<PID>] TID=[<TID>] ++TargetInfoCache::ShouldGetTargetInfo
Verbose SDW PID=[<PID>] TID=[<TID>] --TargetInfoCache::ShouldGetTargetInfo
Error SDW PID=[<PID>] TID=[<TID>] FCP target information is null/empty
Error SDW PID=[<PID>] TID=[<TID>] iSCSI target information is null/empty

例3

Verbose SDW PID=[<PID>] TID=[<TID>] Getting iSCSI target info
Verbose SDW PID=[<PID>] TID=[<TID>] ++PSHelper::RunCommand
Verbose SDW PID=[<PID>] TID=[<TID>] ++ConfigManager::GetConfigSettingMaxRetryFileExist
Verbose SDW PID=[<PID>] TID=[<TID>] --ConfigManager::GetConfigSettingMaxRetryFileExist
Verbose SDW PID=[<PID>] TID=[<TID>] ++ConfigManager::GetConfigSettingRetryInterval
Verbose SDW PID=[<PID>] TID=[<TID>] --ConfigManager::GetConfigSettingRetryInterval
Critical SDW PID=[<PID>] TID=[<TID>] The running command stopped because the preference variable "ErrorActionPreference" or common parameter is set to Stop: 
===================================================================================
| This cmdlet must be directed to a data vserver.  You are currently connected   |
| to the cluster admin vserver.  See the Toolkit web docs (Show-NcHelp) or online |
| help (Get-Help Connect-NcController -Examples) to learn more about directing   |
| Toolkit cmdlets to a cluster or data vserver as required by Data ONTAP.      |
===================================================================================

  at System.Management.Automation.Runspaces.PipelineBase.Invoke(IEnumerable input)
  at SnapDrive.Nsf.Common.PowerShell.PSHelper.RunCommand(Command command, IEnumerable input)

..

Verbose SDW PID=[<PID>] TID=[<TID>] --PSHelper::RunCommand
Verbose SDW PID=[<PID>] TID=[<TID>] Failed to get iSCSI target node name for StorageSystem: <STORAGESYSTEM>
 
===================================================================================
| This cmdlet must be directed to a data vserver.  You are currently connected   |
| to the cluster admin vserver.  See the Toolkit web docs (Show-NcHelp) or online |
| help (Get-Help Connect-NcController -Examples) to learn more about directing   |
| Toolkit cmdlets to a cluster or data vserver as required by Data ONTAP.      |
===================================================================================


Verbose SDW PID=[<PID>] TID=[<TID>] Getting FC target info
Verbose SDW PID=[<PID>] TID=[<TID>] ++PSHelper::RunCommand
Verbose SDW PID=[<PID>] TID=[<TID>] ++ConfigManager::GetConfigSettingMaxRetryFileExist
Verbose SDW PID=[<PID>] TID=[<TID>] --ConfigManager::GetConfigSettingMaxRetryFileExist
Verbose SDW PID=[<PID>] TID=[<TID>] ++ConfigManager::GetConfigSettingRetryInterval
Verbose SDW PID=[<PID>] TID=[<TID>] --ConfigManager::GetConfigSettingRetryInterval
Critical SDW PID=[<PID>] TID=[<TID>] The running command stopped because the preference variable "ErrorActionPreference" or common parameter is set to Stop: 
===================================================================================
| This cmdlet must be directed to a data vserver.  You are currently connected   |
| to the cluster admin vserver.  See the Toolkit web docs (Show-NcHelp) or online |
| help (Get-Help Connect-NcController -Examples) to learn more about directing   |
| Toolkit cmdlets to a cluster or data vserver as required by Data ONTAP.      |
===================================================================================

  at System.Management.Automation.Runspaces.PipelineBase.Invoke(IEnumerable input)
  at SnapDrive.Nsf.Common.PowerShell.PSHelper.RunCommand(Command command, IEnumerable input)

..

Verbose SDW PID=[<PID>] TID=[<TID>] ++StorageConnectionPool::CleanUpIfStale
Verbose SDW PID=[<PID>] TID=[<TID>] --TargetInfoCacheHelper::GetTargetInfo
Verbose SDW PID=[<PID>] TID=[<TID>] ++TargetInfoCache::ShouldGetTargetInfo
Verbose SDW PID=[<PID>] TID=[<TID>] --TargetInfoCache::ShouldGetTargetInfo
Error SDW PID=[<PID>] TID=[<TID>] FCP target information is null/empty
Error SDW PID=[<PID>] TID=[<TID>] iSCSI target information is null/empty
Verbose SDW PID=[<PID>] TID=[<TID>] --TargetInfoCache::AddTargetInfoForStorageSystem

 