AFF-A400では、BMCの更新後にシャーシの電源がデグレード状態になります

Views:
57
Visibility:
Public
Votes:
0
Category:
aff-series<a>2009168737</a>
Specialty:
hw
Last Updated:

環境

  • BMC 13.6
  • AFF A400
  • FAS8300
  • FAS8700
  • ローライン(100V-120V)回路

問題

  • AutoSupport メッセージを受信しました:

HA Group Notification (CHASSIS POWER SUPPLY DEGRADED: PS 1) ERROR

  • 両方の電源装置についてEMSメッセージで次の情報が報告されます。
Tue May 17 10:05:36 -0400 [node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 VIN is Critical Low (117700 mV)
Tue May 17 10:05:36 -0400 [node-02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 VIN is Critical Low (118800 mV)