In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

"SPLinkDownAlert" エラーが発生し、数分後に自動的にクリアされます

Views:
28
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

環境

  • FAS8200
  • ONTAP 9
  • サービス プロセッサ(SP)

問題

  • ONTAP System Manager イベントに対する出力を次に示します。

hm.alert.raised: Alert Id = SPLinkDownAlert,Alerting Resource = SP Config raised by monitor controller

  • 「 system service-processor network show 」の出力は次のとおりです。

 

  • Node-01

Status: online

LinkState: down

SP Network Setup Status: succeeded

 

  • Node-02

Status: online

LinkState: up

SP Network Setup Status: succeeded

  • 「 sysconfig -a 」の出力から、サービスプロセッサ( SP )はオンラインですが、 IP のステータスは不明です。



 Service Processor       Status: Online
 Firmware Version:   5.7
  Mgmt MAC Address:   00:A0:98:4E:F5:9E
  Ethernet Link:    down, full duplex, auto-neg complete
  Using DHCP:      no
 IPv4 configuration:
  IP Address:     unknown
  Netmask:       unknown
  Gateway:       unknown
 IPv6 configuration:      Disabled
 [Service Processor cached network info

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support