In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

FAS2750 の BMC 警告 LED が黄色く点灯している

Views:
15
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

環境

FAS2750

問題

  • system controller service-event show は空です
  • sp-latest-ipmi AutoSupport のセクションに理由が表示されます。
 
tag  origin  fld                     fault reason                       count   time
---- ------- ----                     -------------                      ------   -----
1    bmc     /chassis-1/controller-b  P3V3_BATT: Voltage Sensor 26 UNC   1        Wed Mar  9 10:36:52 2022

Fault Lights On:
/chassis-1                                                                              1

/chassis-1/controller-b
  • BMC のコマンドで、バッテリがしきい値の下限に達した system sensors
BMC Node02> system sensors Sensor Name | Current | Unit | Status | LCR | LNC | UNC | UCR -----------------+------------+------------+------------+-----------+-----------+-----------+----------- P3V3_BATT | 2.695 | Volts | nc | 2.538 | 2.695 | 3.308 | 3.448 -----------------+------------+------------+------------+-----------+-----------+-----------+-----------
  • BMC をリブートしても問題 は解決しない:
cluster::> system service-processor reboot-sp -node <nodename>
Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support