環境

AFF / FAS

問題

  • イベントログに次のメッセージが記録されてノードが停止する:

[Node-01:nvram.battery.power.fault:EMERGENCY]: The NVRAM battery is not receiving power. To prevent data loss, the system will shut down in 5 minutes.
[Node-01:callhome.battery.failure:EMERGENCY]: Call home for BATTERY (power fault) CRITICAL.
[Node-01:monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery power fault)

  • ブート時のコンソールメッセージ: 

WARNING:  The battery is experiencing a critical failure:
      - Battery power fault
      Without a working battery, the system cannot retain data
      during a power outage, which can result in data loss.
      Power down the system and verify that the battery is
      properly installed.
      To ignore this failure and boot the system in a mode
      where data loss might occur, press 'c' followed by 'Enter'

  • システムの電源がオンになり、NVRAMバッテリの充電に十分な時間が確保されました
  • SP / BMCファームウェアが最新バージョンに更新されました

 