メインコンテンツまでスキップ

バッテリセンサーが読み取り不能なため、環境がシャットダウンされました

Views:
128
Visibility:
Public
Votes:
0
Category:
fas-systems<a>2008820631</a>
Specialty:
hw
Last Updated:

環境

  • AFF A250
  • ONTAP 9

問題

  • ノードが突然環境のシャットダウンを実行する。
  • パートナーノードでテイクオーバーが実行され、障害が発生したノードで読み取り不能バッテリセンサーに関連するエラーが検出されてシャットダウンが開始されます。
  • EMS ログには次の情報が表示されます。

[node_name:nvmem.battery.unread:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Initial FCC' sensor is unreadable. To prevent data loss, the system will shut down in 5 minutes.
[node_name:nvmem.battery.packInvalid:EMERGENCY]: The incorrect NVMEM battery is installed. Expected part number is 271-00045. To prevent data loss, the system will shut down in 5 minutes.
[node_name:nvmem.battery.unread:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Initial FCC' sensor is unreadable. To prevent data loss, the system will shut down in 5 minutes.
[node_name:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Initial FCC' unreadable) CRITICAL.
[node_name:nvmem.battery.packInvalid:EMERGENCY]: The incorrect NVMEM battery is installed. Expected part number is 271-00045. To prevent data loss, the system will shut down in 5 minutes.
[node_name:monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery initial FCC failed)

または
[node_name: env_mgr: nvmem.battery.unread:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Temp' sensor is unreadable. To prevent data loss, the system will shut down in 5 minutes.
[node_name: env_mgr: nvmem.battery.unread:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Volt' sensor is unreadable. To prevent data loss, the system will shut down in 5 minutes.
[node_name: env_mgr: nvmem.battery.unread:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Curr' sensor is unreadable. To prevent data loss, the system will shut down in 5 minutes.
[node_name: env_mgr: nvmem.battery.unread:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Full Cap' sensor is unreadable. To prevent data loss, the system will shut down in 5 minutes.
[node_name: env_mgr: nvmem.battery.unread:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Charge Curr' sensor is unreadable. To prevent data loss, the system will shut down in 5 minutes.
[node_name: env_mgr: nvmem.battery.unread:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Charge Volt' sensor is unreadable. To prevent data loss, the system will shut down in 5 minutes.
[node_name: env_mgr: nvmem.battery.unread:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Initial Fcc' sensor is unreadable. To prevent data loss, the system will shut down in 5 minutes.
[node_name: env_mgr: nvmem.battery.unread:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Dstg Cycles' sensor is unreadable. To prevent data loss, the system will shut down in 5 minutes.
[node_name: env_mgr: nvmem.battery.unread:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Dsg FET Flt' sensor is unreadable. To prevent data loss, the system will shut down in 5 minutes.

  • SP-LATEST-IPMI / system fru show BMC CLI からの出力:

Bat_Temp      | na  | degrees C   | na   | 0.000 | 0.000 | 5.000 | 60.000 | 75.000 | 127.500   
Bat_Volt      | na  | Volts     | na   | 0.000 | 5.500 | 5.600 | 8.500  | 8.600  | 12.750   
Bat_Curr      | na  | Amps      | na   | na   | na   | na   | 1.200  | 1.520  | 2.540    
Bat_Rem_Cap    | na  | Watts * hour | na   | na   | na   | na   | na    | na    | na     
Bat_Full_Cap    | na  | Watts * hour | na   | na   | na   | na   | na    | na    | na     
Bat_Charge_Curr  | na  | Amps      | na   | na   | na   | na   | 2.200  | 2.300  | 5.100    
Bat_Charge_Volt  | na  | Volts     | na   | na   | na   | na   | 8.900  | 9.000  | 12.750   
Bat_Design_Cap   | na  | Watts * hour | na   | na   | na   | na   | na    | na    | na     
Bat_Initial_Fcc  | na  | Watts * hour | na   | na   | na   | na   | na    | na    | na     
Bat_Dstg_Cycles  | na  | cycles     | na   | na   | 2.000 | 5.000 | na    | na    | na     
Bat_Cycle_Cnt   | na  | cycles     | na   | na   | na   | na   | na    | na    | na     
Bat_Power_Fault  | 0x0 | discrete    | 0x0180| na   | na   | na   | na    | na    | na     
Bat_Dsg_FET_Flt  | na  | discrete    | na   | na   | na   | na   | na    | na    | na     
Bat_Chg_FET_Flt  | na  | discrete    | na   | na   | na   | na   | na    | na    | na     
Bat_Pack_Invalid | na  | discrete    | na   | na   | na   | na   | na    | na    | na

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.