環境

  • SAS
  • I/O モジュール( IOM )

問題

IOMは黄色で点灯し、PHYは「UNKWN LNK」です。

例:

Shelf name:    UNUSED.shelf11
Shelf id:      11
Channel:       N/A
Module:        B
Shelf UID:    
Shelf S/N:    
Term switch:   N/A
Shelf state:   ONLINE
Module state:  OK

               Partial Path   Link    Invalid   Running     Loss    Phy       CRC     Phy
Disk    Port   Timeout        Rate     DWord    Disparity   Dword   Reset     Error   Change
Id     State   Value (ms)    (Gb/s)    Count    Count       Count   Problem   Count   Count
--------------------------------------------------------------------------------------------
[HST0] OK             7       12.0        0           0       0        0         0       9
[HST1] OK             7       12.0        0           0       0        0         0       9
[HST2] OK             7       12.0        1           1       0        0         0       9
[HST3] OK             7       12.0        0           0       0        0         0       9
[HST4] EMPTY          7         NA        0           0       0        0         0       0
[HST5] EMPTY          7         NA        0           0       0        0         0       0
[HST6] EMPTY          7         NA        0           0       0        0         0       0
[HST7] EMPTY          7         NA        0           0       0        0         0       0
[HST8] UNKWN LNK      7         NA        0           0       0        0         0      10
[HST9] OK             7       12.0        0           0       0        0         0      11
[HST10] OK             7       12.0        0           0       0        0         0      11
[HST11] OK             7       12.0        0           0       0        0         0      11
[HST12] EMPTY          7         NA        0           0       0        0         0       0
[HST13] EMPTY          7         NA        0           0       0        0         0       0
[HST14] EMPTY          7         NA        0           0       0        0         0       0
[HST15] EMPTY          7         NA        0           0       0        0         0       0

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.