メインコンテンツまでスキップ

FAS2650、FAS8200、AFF A200、AFF A300、AFF A800の各システムで、「nvmem.battery.wrongCharge」というEMSメッセージが数秒間報告され、リカバリされます。

Views:
734
Visibility:
Public
Votes:
0
Category:
fas-systems<a>バッテリ</a><a>nvmem バッテリに不正な充電があります</a>
Specialty:
hw
Last Updated:

環境

  • FAS2650 / FAS2620
  • FAS2720 / FAS2750
  • AFF A300 / FAS8200
  • AFF A200
  • AFF A220
  • AFF C190用
  • AFF A800

問題

  • EMSメッセージ nvmem.battery.wrongCharge がトリガーされると、バッテリは数秒後に回復します。

cluster::> event log show -severity * -event *battery*

[hostname: env_mgr: nvmem.battery.wrongCharge:alert]: The NVMEM battery charger is charging the battery even though the battery is not requesting to be charged. To prevent data loss, the system will shut down in 24 hours.
[hostname: env_mgr: nvmem.battery.normalCharge:notice]: The NVMEM battery charging status is normal.

  • system node environment sensors show バッテリの充電が正常であることを報告します。

Bat Present                             PRESENT
Bat Temp                 normal            29 C         0 C         5 C        60 C        75 C
Bat Volt                 normal          8100 mV     5500 mV     5600 mV     8500 mV     8600 mV
Bat Pct Capacity         normal            96 %        39 %        44 %        --          --
Bat Curr                 normal             0 mA       --          --        1200 mA     1520 mA
Bat Rem Cap              normal          1536 mA*hr    --          --          --          --
Bat Full Cap             normal          1536 mA*hr    --          --          --          --
Bat Charge Curr          normal             0 mA       --          --        2200 mA     2300 mA
Bat Charging State                        IDLE
Bat Charge Volt          normal          8200 mV       --          --        8900 mV     9000 mV
Bat Initial FCC          normal          1600 mA*hr    --          --          --          --
Bat Dstg Cycles          normal            26 cycles    2 cycles    5 cycles   --          --
Bat Power Fault                           GOOD
Bat Dcharge FET                             ON
Bat Charge FET                              ON
Bat Cycle Count          normal            15 cycles   --          --          --          --
Bat Learning Active                        OFF
Bat Pack Invalid                            OK

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.