メインコンテンツまでスキップ

Brocade Gシリーズスイッチがファンの障害を報告しています

Views:
152
Visibility:
Public
Votes:
1
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

環境

  • Brocade G610
  • MetroCluster Brocade G610スイッチ
  • Brocade G720
  • MetroCluster Brocade G720スイッチ

問題

  • Brocade G610/G720スイッチの内蔵ファンが障害状態になり、自動でリカバリします。
  • 環境問題はない。
  •  errdump ログには、ファンが内蔵されていても、取り外しと再挿入を行って回復したように見えますが、これは正しくありません。
    • 例:
2021/02/11-14:28:02, [HIL-1206], 586, CHASSIS, ERROR, BrocadeG610, Fan 1 sensor 1 , speed (2649 RPM) below threshold.
2021/02/11-14:28:02, [HIL-1312], 587, CHASSIS, WARNING, BrocadeG610, 1 blower(s) failed. Check all blower units immediately.
2021/02/11-14:28:02, [EM-1034], 588, CHASSIS, ERROR, BrocadeG610, Fan 1 set to faulty, rc=20006.
2021/02/11-14:28:14, [MAPS-1021], 589, FID 128, WARNING, brocade-sw1, RuleName=defCHASSISBAD_FAN_MARG, Condition=CHASSIS(BAD_FAN>=1), Obj:Chassis [ BAD_FAN,1] has contributed to switch status MARGINAL.
2021/02/11-14:28:14, [MAPS-1020], 590, FID 128, WARNING, brocade-sw1, Switch wide status has changed from HEALTHY to MARGINAL.
2021/02/11-14:30:01, [EM-1050], 591, CHASSIS, INFO, BrocadeG610, FRU Fan 1 removal detected.
2021/02/11-14:30:01, [EM-1049], 592, CHASSIS, INFO, BrocadeG610, FRU Fan 1 insertion detected.
2021/02/11-14:30:14, [MAPS-1020], 593, FID 128, WARNING, brocade-sw1, Switch wide status has changed from MARGINAL to HEALTHY.
  • fanshow 出力: 
Fan 1 is Ok, speed is 25641 RPM
Fan 2 is Faulty

 
 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.