メインコンテンツまでスキップ

Cisco Nexus スイッチで IO FPGA をアップグレードできません

Views:
314
Visibility:
Public
Votes:
1
Category:
fabric-interconnect-and-management-switches<a>FSE</a><a>2008712866</a>
Specialty:
hw
Last Updated:

環境

  • Cisco Nexus 3232C
  • Cisco Nexus 92300YC
  • Cisco Nexus 9336C-FX2

問題

「環境」セクションの スイッチモデルで EPLD イメージを更新している間に、デバイスがアップグレードをプログラミングしているときに IO FPGA EPLD デバイスがと表示されますが、リブート後に、デバイスには更新されたバージョンは表示されません。


switch1# install epld bootflash:n9000-epld.9.3.4.img module 1
Compatibility check:
Module Type Upgradable Impact Reason
------ ----------------- ---------- ---------- ------
 1 SUP Yes disruptive Module Upgradable
Retrieving EPLD versions.... Please wait.
Images will be upgraded according to following table:

Module  Type   EPLD             Running-Version   New-Version  Upg-Required
------  ----  -------------     ---------------   -----------  ------------
     1   SUP  MI FPGA                   0x9        0x12            Yes
     1   SUP  IO FPGA                   0x9        0x12            Yes


The above modules require upgrade.
The switch will be reloaded at the end of the upgrade
Do you want to continue (y/n) ? [n] y
Proceeding to upgrade Modules.
Starting Module 1 EPLD Upgrade

Module 1 : MI FPGA [Programming] : 100.00% (     64 of      64 sectors)
Module 1 : IO FPGA [Programming] : 100.00% (     64 of      64 sectors)
Module 1 EPLD upgrade is successful.
Module Type Upgrade-Result
------ ------------------ --------------
 1 SUP Success
Module 1 EPLD upgrade is successful.

リブート後の出力:

switch1# show version module 1 epld
EPLD Device Version
---------------------------------------
MI FPGA 0x12
IO FPGA 0x9

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.