  • EシリーズコントローラE5700が古いIOにより予期せず再起動する:

A:4/10/26, 11:18:05 AM (11:18:05) 271217 4010 Controller reset - Shelf 99, Bay A - Reboot Reason : SCSI: REBOOT_ON_ANCIENT_IO

  • MELにVDDとIOP_FAST_TIMEOUT_ERROR のエラーが繰り返し表示される:

B:4/10/26, 11:16:49 AM (11:16:49) 271163 2014 VDD logged an error - Shelf 99, Bay B - SSID: 0, Devnum: 0x010013 LBA: 0xF0F9D8, Blocks: 0x8 - Recovered----> Flags: 0x50302081 = READ: Read Operation, PARITY: Parity data, NOLOCK: Prevent lock during read err., IMMED_CACHE: Request serviced immediately to cache, PI: Error coding in effect, WRITE:_THRU: Write mode write-through, NOCACHE: CDB DPO cache lowest retention----> Recovery: 0x2 = Reconstruction used, ASC: 0x1F = IOP_FAST_TIMEOUT_ERROR, Detection: 0xF80B03DD

B:4/10/26, 11:16:49 AM (11:16:49) 271162 2014 VDD logged an error - Shelf 99, Bay B - SSID: 0, Devnum: 0x010013 LBA: 0xEF1BD7E8, Blocks: 0x8 - Recovered----> Flags: 0x50302081 = READ: Read Operation, PARITY: Parity data, NOLOCK: Prevent lock during read err., IMMED_CACHE: Request serviced immediately to cache, PI: Error coding in effect, WRITE:_THRU: Write mode write-through, NOCACHE: CDB DPO cache lowest retention----> Recovery: 0x2 = Reconstruction used, ASC: 0x1F = IOP_FAST_TIMEOUT_ERROR, Detection: 0xF80B03DD

B:4/10/26, 11:16:49 AM (11:16:49) 271161 2014 VDD logged an error - Shelf 99, Bay B - SSID: 0, Devnum: 0x010013 LBA: 0x7C535E90, Blocks: 0x28 - Recovered----> Flags: 0x50302001 = READ: Read Operation, NOLOCK: Prevent lock during read err., IMMED_CACHE: Request serviced immediately to cache, PI: Error coding in effect, WRITE:_THRU: Write mode write-through, NOCACHE: CDB DPO cache lowest retention----> Recovery: 0x2 = Reconstruction used, ASC: 0x1F = IOP_FAST_TIMEOUT_ERROR, Detection: 0xF80B03DD

  • コアダンプがキャプチャされる場合とされない場合があります。
  • データ伝送速度の低下が報告されました。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.