メインコンテンツまでスキップ

DS460C:ディスク挿入後にPHY Xが不明なリンク速度を報告する

Views:
4
Visibility:
Public
Votes:
0
Category:
disk-shelves<a>2009955739</a>
Specialty:
hw
Last Updated:

環境

DS460Cシェルフ

問題

  • で報告される温度アラート ems-log 

 [Node-01: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
 [Node-01: dsa_worker3: ses.status.temperatureWarning:alert]: DS460-12 (S/N XXXXXXXXXXXXXXX) shelf 12 on channel 0b temperature warning for Temperature sensor 22: not installed or failed. Current temperature: 0 C (32 F). This module is on the front of the shelf 2nd drawer from the top, module B sensor 1.
 [Node-01: dsa_worker3: ses.status.temperatureWarning:alert]: DS460-12 (S/N XXXXXXXXXXXXXXX) shelf 12 on channel 0b temperature warning for Temperature sensor 27: not installed or failed. Current temperature: 0 C (32 F). This module is on the front of the shelf 4th drawer from the top, module B sensor 2.
 [Node-01: dsa_worker5: ses.status.temperatureWarning:alert]: DS460-12 (S/N XXXXXXXXXXXXXXX) shelf 12 on channel 0b temperature warning for Temperature sensor 20: not installed. Current temperature:  C ( F). This module is on the front of the shelf 1st drawer from the top, module B sensor 1.
 [Node-01: dsa_worker5: ses.status.temperatureWarning:alert]: DS460-12 (S/N XXXXXXXXXXXXXXX) shelf 12 on channel 0b temperature warning for Temperature sensor 21: not installed. Current temperature:  C ( F). This module is on the front of the shelf 1st drawer from the top, module B sensor 2.
 [Node-01: dsa_worker5: ses.status.temperatureWarning:alert]: DS460-12 (S/N XXXXXXXXXXXXXXX) shelf 12 on channel 0b temperature warning for Temperature sensor 23: not installed. Current temperature:  C ( F). This module is on the front of the shelf 2nd drawer from the top, module B sensor 2.

  • 不明なリンクレートが報告されました: 

[Node-01: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "X", module "B", drawer "X", PHY "X"is reporting an unknown link rate.
 [Node-01: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "X", module "B", drawer "X", PHY "X" is reporting an unknown link rate.
 [Node-01: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "X", module "B", drawer "X", PHY "X" is reporting an unknown link rate.
 [Node-01: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "X", module "B", drawer "X", PHY "X" is reporting an unknown link rate.

  • ENVIRONMENT セクションレポート 

DCM installed element list: 1, 2, 3, 4, 5, 6, 7, 9, 10; with error: none
 DCM information by element:
  [1] Serial number: XXXXXXXXXX  Part number: 111-04834+A0
    Type: SASDRWR  Vendor: NETAPP  Firmware version: 01200803
  .......
  [8] Serial number:<N/A> Part number: <N/A>
     Type: <N/A> Vendor: <N/A> Firmware version: <N/A>

  • Storage-fault セクションレポート: 

Enclosure Status: critical
Channel: 0b
Shelf: 12
Shelf Type: DS460-12
Product Serial Number: XXXXXXXXXXXXX
Module Type: IOM12 

.....


Temperature Sensors:
Element Status      Status Bytes  Status Descriptions
 .....
 22: UNKNOWN       06,00,14,00   
 23: OK         01,00,2D,00   
 24: OK         01,00,29,00   
 25: OK         01,00,31,00   
 26: OK         01,00,31,00   
 27: UNKNOWN       06,00,14,00  
 ....
 
 
 Drawers Control Module:
Element Status            Status Bytes  Status Descriptions
  1 [IOM12 A]   : OK         01,00,01,01   REPORT, TYPE BIT0
  2 [IOM12 A]   : OK         01,00,01,01   REPORT, TYPE BIT0
  3 [IOM12 A]   : OK         01,00,01,00   REPORT
  4 [IOM12 A]   : OK         01,00,01,01   REPORT, TYPE BIT0
  5 [IOM12 A]   : OK         01,00,01,01   REPORT, TYPE BIT0
  6 [IOM12 B]   : OK         01,00,01,01   REPORT, TYPE BIT0
  7 [IOM12 B]   : OK         01,00,01,01   REPORT, TYPE BIT0
  8 [IOM12 B]   : NOT AVAILABLE    07,00,00,00  
  9 [IOM12 B]   : OK         01,00,01,01   REPORT, TYPE BIT0
 10 [IOM12 B]   : OK         01,00,01,01   REPORT, TYPE BIT0

  • IOMを再装着/交換しても問題が残る
  • ドロワーの交換ヘルプなし 

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 

  • この記事は役に立ちましたか?