エラー!BES-53248クラスタスイッチのRCFアップグレード中に行番号XXXの構成スクリプトファイルにエラーが発生しました

Views:
12
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

環境

  • ONTAP 9
  • BES-53248クラスタスイッチ。

問題

  • BES-53248クラスタスイッチでRCFのアップグレード中に次のエラーが表示される。
interface 0/17-0/24
An invalid interface range has been used for this function. An interface range must be 1000 characters or less.
no shutdown
Command not found / Incomplete command : no shutdown
Error! in configuration script file at line number 187.
CLI Command :: no shutdown.
Aborting script.
Execution of configuration script 'BES-53248-RCF-v1.12-Cluster-HA.scr' could not be completed.
WARNING:
The running configuration may not be the desired configuration. You might want to reload the saved configuration.
 
  • スイッチログからは、両方のスイッチが2つの10GbEポート(0/1および0/2)と2つの100GbEポート(0/55および0/56)のみを使用していることがわかります。

*************** show port all ***************

         Admin    Physical   Physical   Link   Link   LACP   Actor
Intf    Type   Mode    Mode     Status    Status Trap   Mode   Timeout
--------- ------ --------- ---------- ---------- ------ ------- ------ --------
0/1        Enable   10G Full   10G Full   Up    Enable  Enable long
0/2        Enable   10G Full   10G Full   Up    Enable  Enable long
0/3        Enable   Auto          Down   Enable  Enable long
0/4        Enable   Auto          Down   Enable  Enable long
0/5        Enable   Auto          Down   Enable  Enable long
0/6        Enable   Auto          Down   Enable  Enable long
0/7        Enable   Auto          Down   Enable  Enable long
0/8        Enable   Auto          Down   Enable  Enable long
0/9        Enable   Auto          Down   Enable  Enable long
0/10        Enable   Auto          Down   Enable  Enable long
0/11        Enable   Auto          Down   Enable  Enable long
0/12        Enable   Auto          Down   Enable  Enable long
0/13        Enable   Auto          Down   Enable  Enable long
0/14        Enable   Auto          Down   Enable  Enable long
0/15        Enable   Auto          Down   Enable  Enable long
0/16        Enable   Auto          Down   Enable  Enable long
0/55    PC Mbr Enable   Auto     100G Full  Up    Enable  Enable long
0/56    PC Mbr Enable   Auto     100G Full  Up    Enable  Enable long

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.