メインコンテンツまでスキップ

故障LEDが点灯し、PCMステータスが「P SHELF FAULT RQSTD」と表示される

Views:
63
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

環境

  • FAS26X0
  • FAS2750

問題

  • コントローラの障害LEDが点灯している。
  • storage show fault -v 次の情報が表示されます。

Enclosure Status: critical
Channel: 0a
Shelf: 0
Shelf Type: DS212-12
Product Serial Number: SHJSG1751000163
Module Type: IOM12E

Disk Elements:
Element Status          Status Bytes  Status Descriptions
  0 [Bay  0]: OK         01,00,00,00   
  1 [Bay  1]: OK         01,01,00,20   FAULT REQSTD
  2 [Bay  2]: OK         01,02,00,00   
  3 [Bay  3]: OK         01,03,00,20   FAULT REQSTD
  4 [Bay  4]: OK         01,04,00,00   
  5 [Bay  5]: OK         01,05,00,20   FAULT REQSTD
  6 [Bay  6]: OK         01,06,00,00   
  7 [Bay  7]: OK         01,07,00,20   FAULT REQSTD
  8 [Bay  8]: OK         01,08,00,00   
  9 [Bay  9]: OK         01,09,00,20   FAULT REQSTD
 10 [Bay 10]: OK         01,0A,00,00   
 11 [Bay 11]: OK         01,0B,00,20   FAULT REQSTD
  0 [Bay  0]:           FF,00,00,00   
  0 [Bay  0]:           FF,00,00,00   
  

Vendor Unique Element 85-IOM12E: (ACP)
Element Status            Status Bytes  Status Descriptions
 1 [IOM12E A]   : CRITICAL      02,18,00,00   NO ACPP, INBACP
  2 [IOM12E B]   : OK         01,18,00,00   NO ACPP, INBACP

Vendor Unique Element 88-IOM12E: (PCM)
Element Status      Status Bytes  Status Descriptions
  1: OK         01,01,80,00  SP SHELF FAULT RQSTD
  2: OK         01,01,80,00   SP SHELF FAULT RQSTD

  • EMSから 複数のセンサーエラーが報告される

3/17/2022 09:55:32  node01   ALERT      hm.alert.raised: Alert Id = SPNotConfiguredAlert , Alerting Resource = SP Config raised by monitor controller
3/17/2022 09:00:00  node01   ALERT      monitor.shelf.fault: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
3/17/2022 09:00:00  node02   ALERT      monitor.shelf.fault: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
3/17/2022 08:11:57  node02   ALERT      hm.alert.raised: Alert Id = SPNotConfiguredAlert , Alerting Resource = SP Config raised by monitor controller
3/17/2022 08:05:32  node01   ALERT      hm.alert.raised: Alert Id = SPNotConfiguredAlert , Alerting Resource = SP Config raised by monitor controller
3/17/2022 08:00:00  node01   ALERT      monitor.shelf.fault: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
3/17/2022 08:00:00  node02   ALERT      monitor.shelf.fault: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
3/17/2022 07:00:00  node01   ALERT      monitor.shelf.fault: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
3/17/2022 07:00:00  node02   ALERT      monitor.shelf.fault: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 

  • この記事は役に立ちましたか?