1つのノードだけで温度が上昇し、両方の電源装置に障害が発生していることが報告されます
環境
問題
- 1つのAFF A250ノードだけで、シャーシの温度が高く、2つの電源装置に障害が発生したことが報告されます例:
::>event log show -event monitor*,chassis*
Severity Event
--------- ----------------------------------------------
NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 In Fault is Unreadable
NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Fan is Unreadable
NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 FB Hot is Unreadable
NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Hot is Unreadable
NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Inlet is Unreadable
ERROR callhome.chassis.hitemp: Call home for CHASSIS OVER TEMPERATURE
EMERGENCY monitor.globalStatus.critical: Power Supply Status Critical: PSU2, PSU1. Chassis temperature is too high..
ERROR monitor.temp.unreadable: The controller temperature (PSU2 FB Hot) is not readable.
ERROR monitor.temp.unreadable: The controller temperature (PSU2 Hot) is not readable.
ERROR monitor.temp.unreadable: The controller temperature (PSU2 Inlet) is not readable.
ERROR monitor.temp.unreadable: The controller temperature (PSU1 FB Hot) is not readable.
ERROR monitor.temp.unreadable: The controller temperature (PSU1 Hot) is not readable.
ERROR monitor.temp.unreadable: The controller temperature (PSU1 Inlet) is not readable.
ERROR callhome.chassis.ps.degraded: Call home for CHASSIS POWER SUPPLY DEGRADED: PS 1
EMERGENCY monitor.globalStatus.critical: Power Supply Status Critical: PSU2, PSU1.
ERROR callhome.chassis.power: Call home for CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU2, PSU1.
ALERT monitor.chassisPower.degraded: Chassis power is degraded: Power Supply Status Critical: PSU2,PSU1.
NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 Hot is Unreadable
NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 Inlet is Unreadable
NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Out Fault is Unreadable
NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Warning is Unreadable
NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 In Fault is Unreadable
NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Fan is Unreadable
NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 FB Hot is Unreadable
NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Hot is Unreadable
NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Inlet is Unreadable
- パートナーノードですべてのセンサーに問題はありません:
::> system controller environment show
Node FRU Name State
------------------ ------------------------------ -----------
netappv17-01 PSU2 GOOD
netappv17-01 PSU1 GOOD
netappv17-02 PSU2 unknown
netappv17-02 PSU1 unknown
- 1つの内蔵NSM8Eモジュールレポート:
[dsa_worker3: ses.status.enclWarn:error]: NS224NSM8E (S/N SHJHU0123456789) shelf 0 on channel 0s disk enclosure warning for Enclosure 1: VPD EEPROMs mismatch or unreadable. This element is on the unknown location.[dsa_worker3: ses.status.ModuleWarn:alert]: NS224NSM8E (S/N SHJHU0123456789) shelf 0 on channel 0s PCI switch warning for PCI Switch 2: non-critical status; Backplane VPD SEEROM corrupt or unreadable. This element is on the rear of the shelf at the bottom, on shelf module (B).storage show faultの出力に示された順序で指定されており、
Enclosure Status: non-criticalChannel: 0sShelf: 0Shelf Type: NS224NSM8EModule Type: NSM8EEnclosure:Element Status Status Bytes Status Descriptions1: NONCRITICAL 03,00,00,00PSM:Element Status Status Bytes Status Descriptions1 [NSM8E A] : NONCRITICAL 03,0C,00,00 MIDPLANE VPD FAULT, MASTER2 [NSM8E B] : NONCRITICAL 03,04,00,00 MIDPLANE VPD FAULT- 問題はPSUおよびノードの再設置後も維持されます。
- 問題は正常に動作しているPSUを使用したままです。
- 問題 は、1つのシャーシスロットに沿ってコントローラを交換します。