NS224モジュールのファームウェアの不一致および複数の環境エラーです
環境
- NS224シェルフ
- NSM100 ファームウェアのアップグレード
問題
- 両方のモジュールが機能しており、システムがマルチパスでデータを適切に提供しています。
- NSM100モジュールのファームウェアアップグレード中、自動アップグレードプロセスが完了 しない例:
Tue Jun 14 18:42:52 [node_name-02: dsa_disc: ses.mismatch.fw.version:error]: The disk shelf modules on disk shelf 0x.0 are running two different firmware versions. Disk shelf module A is running 0121, and disk shelf module B is running .
Tue Jun 14 18:42:52 [node_name-02: dsa_disc: sfu.firmwareDownrev.shelf:error]: Shelf 0x.shelf0 has downrev firmware.
- 1つのNSM100 Bに関連する複数のエラー例:
::> storage shelf show -shelf 1.0 -instance
Shelf Name: 1.0
Stack ID: 1
Shelf ID: 0
...
Shelf State: Online
Status: Normal
Boot device "2" error detected.
Temperature reported by temperature sensor "17" exceeds the specifications for the disk shelf or its components.
Temperature reported by temperature sensor "16" exceeds the specifications for the disk shelf or its components.
Temperature reported by temperature sensor "15" exceeds the specifications for the disk shelf or its components.
Temperature reported by temperature sensor "14" exceeds the specifications for the disk shelf or its components.
Temperature reported by temperature sensor "13" exceeds the specifications for the disk shelf or its components.
Temperature reported by temperature sensor "12" exceeds the specifications for the disk shelf or its components.
DIMM "8" error detected. DIMM is located in the DIMM slot 4 in the bottom shelf module (B).
DIMM "7" error detected. DIMM is located in the DIMM slot 3 in the bottom shelf module (B).
DIMM "6" error detected. DIMM is located in the DIMM slot 2 in the bottom shelf module (B).
DIMM "5" error detected. DIMM is located in the DIMM slot 1 in the bottom shelf module (B).
Critical error detected in module "2".
Coin cell battery "2" error detected.
sysconfig -M出力でモジュールBが報告されていません。例:
::> system node run -node node_name-01 -command sysconfig -M
...
!NS224NSM100-MODULE!012345678910!111-04256+B3!1D!!
!NS224NSM100-MODULE!!!!!
- NSM100 Bの再起動、再装着、交換後も問題 は維持されます。
- NSM100 Aのソフトリブートにより、モジュールBを一時的に問題なく検出できます。
- NSM100 Aのハードリブートにより、最初の問題 が複製され、モジュールBがエラーを報告します。