環境

  • AFF C400用
  • NS224

問題

  • switch-02は自動的に登録されず、  system health alert show コマンドでエラーMissingPathFromSwitchToNSM_Alert表示されます。 

[2024-08-19 11:55:41.622] cluster-02::> system health alert show
[2024-08-19 11:55:44.251]         Node: node-01
[2024-08-19 11:55:44.251]       Alert ID: MissingPathFromSwitchToNSM_Alert
[2024-08-19 11:55:44.251]       Resource: Shelf Module: 1.0:A
[2024-08-19 11:55:44.251]       Severity: Major
[2024-08-19 11:55:44.251]    Indication Time: Mon Aug 19 11:50:39 2024
[2024-08-19 11:55:44.251]       Suppress: false
[2024-08-19 11:55:44.251]      Acknowledge: false
[2024-08-19 11:55:44.251]    Probable Cause: Shelf 1.0 module A is connected to only one storage
[2024-08-19 11:55:44.251]            switch.
[2024-08-19 11:55:44.251]    Possible Effect: Access to shelf 1.0 module A can be lost due to a
[2024-08-19 11:55:44.251]            switch failure.
[2024-08-19 11:55:44.251]  Corrective Actions: Connect shelf 1.0 module A to two storage switches,
[2024-08-19 11:55:44.251]            following the guide applicable to your shelf.


system health subsystem show, コマンドを使用する SAS-connect_Cluster とdegraded になります。 

[2024-03-15 13:31:47.756] cluster-02::> system health subsystem show
[2024-03-15 13:31:50.458] Subsystem      Health
[2024-03-15 13:31:50.458] ----------------- ------------------
[2024-03-15 13:31:50.458] SAS-connect     ok
[2024-03-15 13:31:50.460] Environment     ok
[2024-03-15 13:31:50.468] Memory       ok
[2024-03-15 13:31:50.468] Service-Processor ok
[2024-03-15 13:31:50.473] Switch-Health    ok
[2024-03-15 13:31:50.479] CIFS-NDO      ok
[2024-03-15 13:31:50.479] Motherboard     ok
[2024-03-15 13:31:50.479] IO         ok
[2024-03-15 13:31:50.483] MetroCluster    ok
[2024-03-15 13:31:50.489] MetroCluster_Node ok
[2024-03-15 13:31:50.497] FHM-Switch     ok
[2024-03-15 13:31:50.497] FHM-Bridge     ok
[2024-03-15 13:31:50.502] SAS-connect_Cluster degraded

  • switch-02は手動でsystem switch ethernet create に登録されます が、CDPではなくSNMPに登録されているためです。

[2024-04-08 13:35:34.430] cluster-02::*> system w switch ethernet show
[2024-04-08 13:36:41.841] Switch            Type         Address      Model
[2024-04-08 13:36:41.845] --------------------------- ------------------ ---------------- ---------------
[2024-04-08 13:36:41.909]
[2024-04-08 13:36:41.927] switch-01(XXXXXXXXXXX) storage-network 12.345.678.90   N9K-C9336C-FX2
[2024-04-08 13:36:41.948]    Serial Number: XXXXXXXXXXX
[2024-04-08 13:36:41.948]     Is Monitored: true
[2024-04-08 13:36:41.948]        Reason: None
[2024-04-08 13:36:41.948]   Software Version: Cisco Nexus Operating System (NX-OS) Software, Version
[2024-04-08 13:36:41.958]            10.2(6)
[2024-04-08 13:36:41.966]    Version Source: CDP/ISDP
[2024-04-08 13:36:41.966]
[2024-04-08 13:36:41.990] switch-02(XXXXXXXXXXX) storage-network 12.345.678.91   N9K-C9336C-FX2
[2024-04-08 13:36:42.002]    Serial Number: XXXXXXXXXXX
[2024-04-08 13:36:42.002]     Is Monitored: true
[2024-04-08 13:36:42.002]        Reason: None
[2024-04-08 13:36:42.002]   Software Version: Cisco Nexus Operating System (NX-OS) Software, Version
[2024-04-08 13:36:42.002]            10.2(6)
[2024-04-08 13:36:42.002]    Version Source: SNMP

  • MissingPathFromSwitchToNSM_Alert 手動で登録すると消えますが、SwitchLinkDiscoveryProtocol_Alert  が表示されます。

[2024-04-08 13:33:30.940] cluster-02::> system health ala ert show
[2024-04-08 13:33:33.244]         Node: cluster-02-01
[2024-04-08 13:33:33.250]       Alert ID: SwitchLinkDiscoveryProtocol_Alert
[2024-04-08 13:33:33.264]       Resource: switch-02(XXXXXXXXXXX)
[2024-04-08 13:33:33.264]       Severity: Minor
[2024-04-08 13:33:33.264]    Indication Time: Mon Mar 18 15:19:40 2024
[2024-04-08 13:33:33.274]       Suppress: false
[2024-04-08 13:33:33.274]      Acknowledge: false
[2024-04-08 13:33:33.299]    Probable Cause: The ethernet switch is using an unsupported link
[2024-04-08 13:33:33.299]            discovery protocol.
[2024-04-08 13:33:33.299]    Possible Effect: The change of the link discovery protocol on the
[2024-04-08 13:33:33.299]            switch is not supported. The connected device will not
[2024-04-08 13:33:33.315]            appear in link layer discovery commands.
[2024-04-08 13:33:33.315]  Corrective Actions: Revert the discovery protocol change on the switch.

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.