環境

  • MetroCluster FC
  • FabricSwitchPowerFail_Alert
  • 電源のメンテナンス
  • Cisco DS-9148S-K9

問題

  • ノード cluster01_01 からの HA グループ通知 (DISK REDUNDANCY FAILED) ERROR
  • vsan 1 にがありません show int port-channel 1
CISCO9148S-FAB1:>show int port-channel 1
port-channel1 is trunking
Hardware is Fibre Channel
Port WWN is 24:01:00:dx:xx:x8:x7:x0
Admin port mode is E, trunk mode is on
snmp link state traps are enabled
Port mode is TE
Port vsan is 1
Speed is 32 Gbps
Logical type is core
Trunk vsans (admin allowed and active) (10,20)
Trunk vsans (up)                       (10,20)
  • 正しい出力:
Cisco9148S-FAB1# show int port-channel 1
port channel1 is trunking
Hardware is Fibre Channel
Port WWN is xx:01:8x:60:4x:20:6x:x0
Admin port mode is E, trunk mode is on
snmp link state traps are enabled
Port mode is TE
Port vsan is 1
Speed is 32 Gbps
Logical type is core
Trunk vsans (admin allowed and active) (1,10,20,50,60)
Trunk vsans (up) (1,10,20,50,60)
Trunk vsans (isolated) ()
Trunk vsans (initializing) ()

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.