メインコンテンツまでスキップ

MetroCluster IPリモートドライブでディスクスクラビングパリティに整合性がありません

Views:
6
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

環境

  • MetroCluster IP
  • ONTAP 9

問題

Disk scrub parity inconsistencyがトリガーされるAutoSupport
 
EMSログのエラーメッセージに、書き込み署名の不整合が検出されたことが示されています
 
例:

Fri Aug 06 02:52:39 +0000 [ClusterB-N1: scsi_cmdblk_strthr_admin: scsi.cmd.checkCondition:error]: Disk device 0m.i2.1L121: Check Condition: CDB 0x28:966c9600:0200: Sense Data SCSI:recovered error -  (0x1 - 0xb 0x97 0x97)(93).
Fri Aug 06 02:52:39 +0000 [ClusterB-N1: disk_server_1: disk.ioRecoveredError.retry:info]: Recovered error on disk 0m.i2.1L121: op 0x28:966c9600:0200 sector 10 SCSI:recovered error - Disk used internal retry algorithm to obtain data (1 b 97 97) (94) Disk 0m.i2.1L121 Shelf 14 Drawer 3 Slot 9 Bay 33 [NETAPP   X377_HLBRE10TA07 NA01] S/N [] UID [5000CCA2:A23F774C:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
Fri Aug 06 02:52:39 +0000 [ClusterB-N1: disk_server_1: disk.IO.status:debug]: params: {'deviceName': '0m.i2.1L121', 'returnCode': '5', 'pathRetryCount': '0', 'adapterStatus': '0x0', 'cdb': '0x28:966c9600:0200', 'basicTimeout': '14', 'iASCQ': '0x97', 'iSenseKey': '0x1', 'sSenseCode': '', 'ETime': '94', 'iASC': '0xb', 'victimRetryCount': '0', 'sSenseKey': 'SCSI:recovered error', 'targetStatus': '0x2', 'disk_information': 'Disk 0m.i2.1L121 Shelf 14 Drawer 3 Slot 9 Bay 33 [NETAPP   X377_HLBRE10TA07 NA01] S/N [] UID [00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]', 'retryCount': '0', 'pathsTried': '0', 'timeoutRetryCount': '0'}
Fri Aug 06 02:52:39 +0000 [ClusterB-N1: raidio_thread: raid_scrub_lw_id_inconsist_1:notice]: params: {'owner': '', 'rg': '/NodeB1_data_aggr01/plex1/rg0', 'more_stripes': '-1', 'stripe': '315462336'}
Fri Aug 06 05:00:01 +0000 [ClusterB-N1: config_thread: raid.rg.scrub.summary.lw:notice]: Scrub found 64 RAID write signature inconsistencies in /Node1_data_aggr01/plex1/rg0.
Fri Aug 06 05:00:02 +0000 [ClusterB-N1: config_thread: callhome.dsk.scrub.parity:alert]: Call home for
DISK SCRUB PARITY INCONSISTENCY

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.