メインコンテンツまでスキップ

ATTO FibreBridge ONTAPのEMSログに「Error:FC Port FC_portX offline」というエラーが報告されます

Views:
38
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster<a>SFP</a><a>ATTO Fibrebridge 7500N</a><a>FCスイッチ</a>
Last Updated:

環境

  • MetroCluster
  • ATTO 7500N ファイバブリッジ
  • ATTO 7600N ファイバブリッジ 
  • ATTO FibreBridgeイベントログにサポートされていないSFPメッセージが記録されます
    • INFO Unqualified SFP (0x0000000x) on FC Port x

問題

  • ATTOブリッジのいずれかのFCポートでオフラインで次のエラーが報告されています。

[hostname: dsbridge_admin: fc.bridge.fc.port.alert:alert]: Fibre Channel FibreBridge7500N Bridge ATTO_200000xxxxxxx4c0 S/N: FB7500Nxxxxxx WWN: 200000xxxxxxxxx FC Port FC_PORT1 offline.

[hostname: schmd: hm.alert.raised:alert]: Alert Id = StorageBridgePortDown_Alert , Alerting Resource = 210000xxxxxxxxx raised by monitor system-connect

[hostname: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process schm: StorageBridgePortDown_Alert[210000xxxxxxxxx].

  • storage bridge show -fields fc-port-index-list,fc-port-oper-state-list 1つのFCポートがオフラインとして表示されます。

例:
name              fc-port-index-list fc-port-oper-state-list
----------------- ------------------ -----------------------
ATTO_200000xxxxxxx4c0    1,2   offline,online <<<< FC port 1 offline
ATTO_200000xxxxxxx480   1,2   online,online
2 entries were displayed.

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.