SVM DRの更新/初期化が「Unable to generate baseline for table sis」というエラーで失敗する
環境
- ONTAP
問題
- SVM DRの更新/初期化が失敗し、次のエラーが表示されます:
Failed to generate baseline. Reason: Unable to generate baseline for table sis. The system might be busy, retry the operation after some time.
Execute "snapmirror show -destination-vserver <DESTINATION-VSERVER> -fields last-transfer-error,unhealthy-reason -expand" to check if the constituent volumes have encountered errors.
/etc/log/mlog/crs.log次のエラーが表示されます:
[kern_crs:info:5583] 0x809262d00: 0: ERR: crs_internal: Baseline fetch failed for table sis - Loop detected in next() for table sis.
Next on ""vserver name""volume path"" returned ""vserver name""volume path"". {in write_object_rows_to_file() at src/tables/crsa/crs_internal.cc:2599}
[kern_crs:info:5583] 0x80925ce00: 0: ERR: crs_streams: Unable to generate a local baseline for 6a368d57-a987-11ea-8b97-d039ea14dafc
{in generate_a_local_baseline_imp() at src/tables/crsa/crs_stream_operational_attributes.cc:1262}
- snapmirror-audit.logにSVM DRの更新の証拠がない