Elementソフトウェアの「Drive has failed Smart health check」というアラートが表示されます
環境
- NetApp Element ソフトウェア
- NetApp SolidFire SF-Series
- NetApp H-Series
問題
NetApp SolidFire Active IQ のエラー:
- エラー コード:
driveHealthFault
- 詳細:
Drive with serial: <xxxxxxxxxx> in slot: <y> has failed SMART overall health check
- 例:
Drive with serial: S3SZABCD01234 in slot: 3 has failed SMART overall health check
- 例:
- エラー コード:
driveHealthFault
- 詳細:
Drive with serial: <xxxxxxxxxx> in slot: <y>, Drive should be replaced. SMART data indicates Non-volatile capacitance is failing, raw critical bytes 0-11: 0x10 0x2a 0x01 0x64 0x0a 0x00 0x00 0x00 0x00 0x00 0x00 0x00
- 例:
Drive with serial: S3T2NX0M305154 in slot: 7, Drive should be replaced. SMART data indicates Non-volatile capacitance is failing, raw critical bytes 0-11: 0x10 0x2a 0x01 0x64 0x0a 0x00 0x00 0x00 0x00 0x00 0x00 0x00
- 例:
- エラー コード:
driveHealthFault
- 詳細:
Drive with serial: <xxxxxxxxxx> in slot: <y>, Drive should be replaced. SMART data indicates health failed, raw critical bytes 0-11: 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
- 例:
Drive with serial: S2TVNB0KA04565 in slot: 1, Drive should be replaced. SMART data indicates health failed, raw critical bytes 0-11: 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
- 例:
- エラー コード:
driveHealthFault
- 詳細:
Drive with serial: <xxxxxxxxxx> in slot: <y>, Drive should be replaced. SMART data indicates it is read only, raw critical bytes 0-11: 0x08 0x31 0x01 0x5e 0x0a 0x00 0x00 0x00 0x00 0x00 0x00 0x00"
- 例:
Drive with serial: S438NA0N609921 in slot: 0, Drive should be replaced. SMART data indicates it is read only, raw critical bytes 0-11: 0x08 0x31 0x01 0x5e 0x0a 0x00 0x00 0x00 0x00 0x00 0x00 0x00"
- 例: