メインコンテンツまでスキップ

AutoSupport がギブバックを拒否した

Views:
25
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

環境

  • ONTAP 8
  • ONTAP 9
  • AutoSupport

問題

ギブバックの拒否がで報告される: 

  • storage failover show-givebackコマンドを実行します

::> storage failover show-giveback
        Partner
Node       Aggregate Giveback Status
-------------- ----------------- ---------------------------------------------
  
Warning: Unable to list entries on node NodeA. RPC: Couldn't make connection
     [from mgwd on node "NodeB" (VSID: -1) to mgwd at 169.254.127.139]
NodeB
    CFO Aggregates   Failed module: autosupport. Giveback vetoed:
                 AutoSupport collection is still in progress.
                 Allow up to 20 minutes for AutoSupport
                 processing after a takeover. Use the
                 "storage failover giveback -override-vetoes
                 true" command to override all veto checks,
                 including AutoSupport collection.
                         
                 Warning: Overriding vetoes to perform a giveback can   
                 be disruptive.
                         
        NodeA_data01    Not attempted yet
2 entries were displayed.

  • storage failover showのコマンドを実行します

::> storage failover show
                Takeover
Node       Partner     Possible State Description
-------------- -------------- -------- -------------------------------------   
NodeA      NodeB      false   Previous giveback failed in module:
                    autosupport. Auto giveback will be
                    initiated in 391 seconds
NodeB      NodeA      -     Waiting for giveback
2 entries were displayed.

  • ONTAP EMSイベント:

[gb.cfo.veto.asup.generalNopart:notice]: AutoSupport vetoed giveback because an AutoSupport message for the down partner node was not yet collected.

 