In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

EMS ログでブロードキャストドメインのパーティショニングされたエラーが報告される

Views:
388
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
network
Last Updated:

のしんだ

環境

  • ONTAP 9
  • イーサネット スイッチ    

問題

  • VIFMGR は、ブロードキャストドメインのポート間で l2ping が発生した場合、次の EMS エントリをログに記録できます。
 [node1: vifmgr: vifmgr.bcastDomainPartition:alert]: Broadcast domain BD1 is partitioned into 2 groups on node node1. The different groups are: {E0M}, {A0A}. LIFs hosted on the ports in this broadcast domain may be at the risk of seeing connectivity issues. 
  • コマンド broadcast-domain show を実行すると、ブロードキャストドメインの正しい情報が返されます。

cluster::*> network port broadcast-domain show
IPspace Broadcast
Name    Domain Name Port                         
------- ----------- -----------------------------
Cluster Cluster
                    node1:e0d             
                    node1:e0f                                   
                    node2:e0d                                       
                    node2:e0f             
                                                      
Default BD1
                    node1:a0a             
                    node1:e0M             
                    node2:a0a             
                    node2:e0M 

 