メインコンテンツへスキップ

「krb5kdc_ERR_C_PRINCIAL_UNKNOWN」エラーでDC接続が失敗すると、CIFS問題が発生します。

Views:
214
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
nas
Last Updated:

環境

  • ONTAP 9
  • Kerberos
  • CIFS

問題

  • ユーザにCIFS共有へのアクセス権がない
  • マシンアカウントを使用しているドメインコントローラへの接続を示すログがエラーKRB5KDC_ERR_C_PRINCIPAL_UNKNOWN で失敗します。

8/18/2022 09:15:58 cluster-01
ERROR secd.cifsAuth.problem: vserver (svm_cifs) General CIFS authentication problem. Error: User authentication procedure failed
CIFS SMB2 Share mapping - Client Ip = 192.168.1.1
[ 0 ms] Login attempt by domain user 'netapp\cifs' using NTLMv1 style security
[ 0] Successfully connected to ip 192.168.0.1, port 445 using TCP
[ 8] Unknown user (KRB5KDC_ERR_C_PRINCIPAL_UNKNOWN)
[ 8] Failed to initiate Kerberos authentication. Trying NTLM.
[ 9] Encountered NT error (NT_STATUS_MORE_PROCESSING_REQUIRED) for SMB command SessionSetup
[ 10] Encountered NT error (NT_STATUS_AUTH_LOGON_FAILURE) for SMB command SessionSetup
[ 10] Unable to connect to NetLogon service on dcsvr.tekunasas.local (Error: RESULT_ERROR_SECD_NO_CONNECTIONS_AVAILABLE)
[ 11] No servers available for MS_NETLOGON, vserver: 6, domain: netapp.local.
**[ 11] FAILURE: Unable to make a connection (NetLogon:NETAPP.LOCAL), result: 6940
[ 12] CIFS authentication failed

  • Active Directory側で、CIFSサーバのマシンアカウントが見つからない

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.