vifmgr.cluscheck.crcerrorsアラートのifstat出力で長いフレームが報告される
環境
- ONTAP 9
- FAS / AFFプラットフォーム
問題
- 長いフレームはの出力に表示され
ifstat
ます。例:
-- interface e1d (5 days, 13 hours, 44 minutes, 30 seconds) --
RECEIVE
Total frames: 438k | Frames/second: 1 | Total bytes: 32232k
Bytes/second: 67 | Total errors: 32047 | Errors/minute: 4
Total discards: 0 | Discards/minute: 0 | Multi/broadcast: 561k
Non-primary u/c: 0 | CRC errors: 0 | Runt frames: 0
Long frames: 32047 | Length errors: 0 | Alignment errors: 0
No buffer: 0 | Pause: 0 | Jumbo: 0
Noproto: 0 | Bus overruns: 0 | LRO segments: 0
...
- ONTAPのバージョンに応じて、次のいずれかのイベントがEMSに記録されます。
[Node1: vifmgr: vifmgr.cluscheck.crcerrors:alert]: Port e1d on node Node1 is reporting a high number of observed CRC errors.
[Node1: vifmgr: vifmgr.cluscheck.crcerrors:alert]: Port e1d on node Node1 is reporting a high number of observed hardware errors, possibly CRC errors.
[Node1: vifmgr: vifmgr.cluscheck.hwerrors:alert]: Port e1d on node Node1 is reporting a high number (at least 1 per 1000 packets) of observed hardware errors (CRC, length, alignment, dropped).
- ポートにMTU 1500が設定されている
- スイッチ側では、スイッチポートは長いフレームを受信していませんが、送信しています。
switch# show interface eth0/10
Ethernet0/10 is up
RX
0 jumbo packets 0 storm suppression bytes
TX
32047 jumbo packets