アグリゲートが再同期中であるため、ONTAP SelectまたはCVOのギブバックが拒否されました
環境
- NetApp ONTAP Select (OTS)
- Cloud Volumes ONTAP(CVO)
- 無停止アップグレード(NDU)
問題
ONTAP Select VMまたはCloud Volumes ONTAPインスタンスのギブバックを完了できず、RAIDモジュールによって拒否されます。
netapp00::> storage failover show-giveback PartnerNode Aggregate Giveback Status-------------- ----------------- ---------------------------------------------Warning: Unable to list entries on node select-01. RPC: Couldn't make connection [from mgwd on node "select-02" (VSID: -1) to mgwd at xxx.xx.xxx.xxx]XXXXXXXX
CFO Aggregates Failed module: raid. Giveback vetoed: Cannot send all specified aggregates home. Use the "event log show -message-name gb.sfo.abort.raid.fm|gb.cfo.abort.raid.fm" command to get more information, and follow the provided corrective actions. To execute the giveback without checks, use the "override-vetoes" parameter. Warning: overriding vetoes may result in a data service outage. aggr2 Not attempted yet aggr1 Not attempted yet3 entries were displayed.- テイクオーバー中のノードがあるため、ノード管理LIFにアクセスできません