In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

外付けシェルフの ACPP エラーが報告されました

Views:
7
Visibility:
Public
Votes:
0
Category:
disk-shelves
Specialty:
hw
Last Updated:

環境

DS224Cディスク シェルフ

問題

  • シェルフの両方の ACP モジュールで障害が報告されます
Fri Sep 24 16:23:10 +0100 [node-01: dsa_worker0: ses.status.ACPError:alert]: DS224-12 (S/N XXXXXXXXXXXXXXX) shelf 24 on channel 9c ACP Processor error for SAS shelf ACP processor 1: critical status ; Alternate Control Path hardware failed This module is on the rear of the shelf at the top left, on shelf module A.
Fri Sep 24 16:23:10 +0100 [node-01: dsa_worker0: ses.status.ACPError:alert]: DS224-12 (S/N XXXXXXXXXXXXXXX) shelf 24 on channel 9c ACP Processor error for SAS shelf ACP processor 2: critical status ; Alternate Control Path hardware failed This module is on the rear of the shelf at the top right, on shelf module B.
Fri Sep 24 16:23:19 +0100 [node-01: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 1b. Check fans, power supplies, disks, and temperature sensors.
Fri Sep 24 16:23:19 +0100 [node-01: statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT
  • これは、次の場合にも CLI に表示されます。
Cluster::> system node run -node <node name> -command storage show fault -v
Enclosure Status: critical
Channel: 1b
Shelf: 24
Shelf Type: DS224-12
Product Serial Number: XXXXXXXXXXXXXXX
Module Type: IOM12
Vendor Unique Element 85-IOM12: (ACP)
Element Status Status Bytes Status Descriptions
1 [IOM12 A] : CRITICAL 02,18,00,40 NO ACPP, INBACP, FAIL
2 [IOM12 B] : CRITICAL 02,18,00,40 NO ACPP, INBACP, FAIL
  • ACP の無効化と再有効化には効果がありません
  • シェルフモジュールを取り付け直しても問題は発生しません
  • シェルフモジュールの交換で問題は解決しません
Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support