外付けシェルフの ACPP エラーが報告されました
環境
DS224Cディスク シェルフ
問題
- シェルフの両方の ACP モジュールで障害が報告されます
Fri Sep 24 16:23:10 +0100 [node-01: dsa_worker0: ses.status.ACPError:alert]: DS224-12 (S/N XXXXXXXXXXXXXXX) shelf 24 on channel 9c ACP Processor error for SAS shelf ACP processor 1: critical status ; Alternate Control Path hardware failed This module is on the rear of the shelf at the top left, on shelf module A.
Fri Sep 24 16:23:10 +0100 [node-01: dsa_worker0: ses.status.ACPError:alert]: DS224-12 (S/N XXXXXXXXXXXXXXX) shelf 24 on channel 9c ACP Processor error for SAS shelf ACP processor 2: critical status ; Alternate Control Path hardware failed This module is on the rear of the shelf at the top right, on shelf module B.
Fri Sep 24 16:23:19 +0100 [node-01: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 1b. Check fans, power supplies, disks, and temperature sensors.
Fri Sep 24 16:23:19 +0100 [node-01: statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT
- これは、次の場合にも CLI に表示されます。
Cluster::> system node run -node <node name>
-command storage show fault -v
Enclosure Status: critical
Channel: 1b
Shelf: 24
Shelf Type: DS224-12
Product Serial Number: XXXXXXXXXXXXXXX
Module Type: IOM12
Vendor Unique Element 85-IOM12: (ACP)
Element Status Status Bytes Status Descriptions
1 [IOM12 A] : CRITICAL 02,18,00,40 NO ACPP, INBACP, FAIL
2 [IOM12 B] : CRITICAL 02,18,00,40 NO ACPP, INBACP, FAIL
- ACP の無効化と再有効化には効果がありません
- シェルフモジュールを取り付け直しても問題は発生しません
- シェルフモジュールの交換で問題は解決しません