In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

「 Active IQ Config Advisor Summary Report 」レポートの「 SAS Cabling Checks 」

Views:
41
Visibility:
Public
Votes:
0
Category:
aff-series
Specialty:
hw
Last Updated:

に適用されます

AFF - A700 S

ONTAP 9.7P4

問題

  • Active IQ Config Advisor Summary Report"" レポート ""SAS Cabling checks

例:

Description:SAS Cabling Checks
Severity :High Impact
Details :Three paths found from controller node name:******* to the stack on port 0a. Only multipath and quad-path configurations are supported.

  • "sysconfig -a" ログにはクアッドパスが正常であることが示されています。

例:

slot 0: SAS Host Adapter 0a (Avago Technologies SAS3008 rev. 2, SAS, <UP>)
  Firmware rev:    13.00.00.00
  NVDATA rev:     11.02.17.08
  Base WWN:      5:00a098:00e3028:84
  Phy State:     [0] Enabled, 12.0 Gb/s
           [1] Enabled, 12.0 Gb/s
           [2] Enabled, 12.0 Gb/s
           [3] Enabled, 12.0 Gb/s

 