メインコンテンツまでスキップ

無効にしたあとにヘルスアラートが誤って生成される、クラスタスイッチのログ収集

Views:
7
Visibility:
Public
Votes:
0
Category:
fas-systems<a>2008742661</a>
Specialty:
hw
Last Updated:

環境

クラスタスイッチログの収集

問題

  •  スイッチログ収集ログインに失敗したことを示すヘルスアラートがシステムに送信されます。

Alert ID:    SwitchAccess_Alert
Subsystem   Switch-Health
Probable Cause   Login_attempts_failed

Corrective Actions   

1) To set up public SSH key authentication on the cluster switch,
run the "system cluster-switch log setup-password" command.
ONTAP requires one-time use of the cluster switch's administrative login credentials
to set up the public SSH key for ONTAP access.
The administrative credentials will be discarded after the setup command is complete.
2) If public SSH key authentication is already configured, log in to the cluster switch
with administrative credentials from an SSH host or serial console to investigate the login failures.
3) To disable tech-support log collection, run the "system cluster-switch log disable-collection" command
に関するネットアップのドキュメントを参照してください。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.