メインコンテンツまでスキップ
NetApp Response to Russia-Ukraine Cyber Threat
In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

環境理由シャットダウン(バッテリ PCT 容量が重要)

Views:
143
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

環境

  • FAS26XX
  • FAS27xx
  • AFF C190用
  • AFF A220
  • FAS80x0

問題

理由による緊急時のシャットダウン Battery PCT capacity critical
 
Jan 02 21:43:08 [nodename:nvmem.battery.fccLowCrit:EMERGENCY]: The NVMEM battery full-charge capacity is critically low (15 ). To prevent data loss, the system will shut down in 20 minutes.
Jan 02 21:43:59 [nodename:nvmem.battery.capLowCrit:EMERGENCY]: The NVMEM battery capacity is critically low (0 cycles). To prevent data loss, the system will shut down in 20 minutes.
Jan 02 21:44:08 [nodename:callhome.battery.failure:EMERGENCY]: Call home for BATTERY (full charge capacity low) CRITICAL.
Jan 02 21:44:29 [nodename:callhome.battery.failure:EMERGENCY]: Call home for BATTERY (capacity low) CRITICAL.
Jan 02 22:00:00 [nodename:monitor.nvramLowBattery:EMERGENCY]: NVRAM battery is dangerously low.
Jan 02 22:03:09 [nodename:monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery PCT capacity critical)
Waiting for PIDS: /usr/sbin/rpcbind 1208.
Terminated
.
Uptime: 117d7h1m47s
System powering down...
 
BMC ログエントリ:
 [IPMI.emergency]: env_mgr triggers OS halt:Battery PCT capacity [IPMI.notice]: 001e | 02 | EVT: 6f03ffff | Sensor 255 | Assertion Event, "Storage OS graceful shutdown" [IPMI.notice]: 001f | 02 | EVT: 0150008f | PVCCIN_CPU | Assertion Event, "Lower Non-critical going low " | Reading: 0.000 | Threshold: 1.502 [IPMI.notice]: 0020 | 02 | EVT: 01520077 | PVCCIN_CPU | Assertion Event, "Lower Critical going low " | Reading: 0.000 | Threshold: 1.249 

バッテリステータスの例:
Bat Present             PRESENT
Bat Temp       failed       -- C      0 C      5 C     56 C     60 C
Bat Volt       failed       -- mV    5500 mV    5600 mV    8500 mV    8600 mV
Bat Pct Capacity   failed       -- %     39 %     44 %     --      --
Bat Curr       failed       -- mA     --      --     1520 mA    1800 mA
Bat Rem Cap      not_available    -- mA*hr   --      --      --      --
Bat Full Cap     failed       -- mA*hr   --      --      --      --
Bat Charge Curr    failed       -- mA     --      --     2400 mA    2900 mA
Bat Charging State  failed        --
Bat Charge Volt    failed       -- mV     --      --     8900 mV    9000 mV
Bat Initial FCC    failed       -- mA*hr   --      --      --      --
Bat Dstg Cycles    failed       -- cycles   2 cycles   5 cycles   --      --
Bat Power Fault            GOOD
Bat Dcharge FET    failed        --
Bat Charge FET    failed        --
Bat Cycle Count    not_available    -- cycles   --      --      --      --
Bat Learning Active not_available    --
Bat Pack Invalid   failed        --

 

 

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support

 

  • この記事は役に立ちましたか?