In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

温度センサーが正常な状態に戻っても、環境シャットダウンが実行されます 2 分以内

Views:
82
Visibility:
Public
Votes:
1
Category:
ontap-9
Specialty:
hw
Last Updated:

に適用されます

  • ONTAP 9
  • サービス プロセッサ(SP)

問題

温度センサーが 2 分以内に正常に戻りましたが、環境シャットダウンしました。

例:

  • EMS の system show temperature は OK ですが、 2 分後にシャットダウンします。

21 Nov 2020 03:40:27 [NSPAVM105: alert] env_mgr monitor chassisTemperature warm: describe_toowarm="CPU0 Temp Margin is critical high (88 C)."
21 Nov 2020 03:40:27 [NSPAVM105: emergency] env_mgr monitor shutdown chassisOverTemp: describe_toohot="CPU0 Temp Margin is critical high. System will be shutdown in 2 minutes"
21 Nov 2020 03:40:37 [NSPAVM105: notice] env_mgr monitor chassisTemperature ok:
21 Nov 2020 03:41:26 [NSPAVM105: emergency] env_mgr callhome chassis overtemp: subject="CHASSIS OVER TEMPERATURE SHUTDOWN"
21 Nov 2020 03:42:28 [NSPAVM105: emergency] statd monitor shutdown emergency: reason="Environmental Reason Shutdown (Temperature critical)"

  • SP イベントでは、温度センサーはすべて正常であることが示されますが、システムは 2 分でシャットダウンします。

Record 1218: Fri Nov 20 19:40:23 2020 [IPMI.notice]: 6b01 | 02 | EVT: 015758f5 | CPU0_Temp_Margin | Assertion Event, "Upper Non-critical going high"
Record 1219: Fri Nov 20 19:40:23 2020 [IPMI.notice]: 6c01 | 02 | EVT: 015958ff | CPU0_Temp_Margin | Assertion Event, "Upper Critical going high"
Record 1220: Fri Nov 20 19:40:33 2020 [IPMI.notice]: 6d01 | 02 | EVT: 8159ccff | CPU0_Temp_Margin | Deassertion Event, "Upper Critical going high"
Record 1221: Fri Nov 20 19:40:33 2020 [IPMI.notice]: 6e01 | 02 | EVT: 8157ccf5 | CPU0_Temp_Margin | Deassertion Event, "Upper Non-critical going high"
Record 1222: Fri Nov 20 19:40:55 2020 [IPMI.notice]: 6f01 | 02 | EVT: 0301ffff | Attn_Sensor1 | Assertion Event, "State Asserted"
Record 1223: Fri Nov 20 19:41:03 2020 [IPMI.notice]: 7001 | 02 | EVT: 0300ffff | Attn_Sensor1 | Assertion Event, "State Deasserted"
Record 1224: Fri Nov 20 19:42:23 2020 [IPMI.emergency]: triggered OS halt: Temperature critical

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support