メインコンテンツまでスキップ

シャーシの PSU に障害が発生すると、システムがシャットダウンします

Views:
160
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

に適用されます

  • FAS8020

問題

  • シャーシの PSU に障害が発生した場合は、次のアラートを受け取ります
 
CHASSIS POWER SUPPLY NEED TO BE REPLACED: PS 1
 
EMS ログが表示される

[Cluster1: power_low_monitor: monitor.chassisPower.degraded:alert]: Chassis power is degraded: Power Supply Status Critical: PSU1.
[Cluster1: power_low_monitor: callhome.chassis.power:error]: Call home for CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU1.
[Cluster1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Power Output has failed
[Cluster1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 has failed
[Cluster1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 is over voltage
  • NMI / が原因で HA ペアの両方のノードがシャットダウンします ウォッチドッグリセット

イベント ログ

[Agent.notice]: 889.353: 128 : PCIe Slot 1 Power Good de-asserted
[Agent.notice]: 889.384: 129 : PCIe Slot 2 Power Good de-asserted
[Agent.notice]: 889.396: 59 : NVRAM 12V Power Good de-asserted
[Agent.notice]: 889.411: 14 : Attention LED (at Midplane) asserted
[Agent.notice]: 889.427: 29 : Non-maskable Interrupt from PCH to CPU asserted
[Agent.notice]: 889.427: 11 : Controller Attention LED asserted
[Agent.notice]: 893.579: 5 : DC Power OK PSU1 de-asserted
[Agent.notice]: 893.580: 9 : Power Supply Fault LED PSU1 asserted
[Agent.notice]: 041.083: 30 : Non-maskable Interrupt to PCH asserted
[Agent.notice]: 133.088: 30 : Non-maskable Interrupt to PCH de-asserted
[IPMI Event.critical]: NMI
[IPMI Event.critical]: L2 watchdog timeout hard reset
[Trap Event.critical]: hwassist l2_watchdog_reset (29)
[IPMI.notice]: 4203 | 02 | EVT: 0150d4ff | Bat_Curr | Assertion Event, "Lower Non-critical going low " | Reading: -1.760 | Threshold: -0.040
[Agent.notice]: 749.130: 145 : SP XDP Interface Enable asserted
[IPMI.notice]: 4303 | 02 | EVT: 6fc804ff | System_Watchdog | Assertion Event, "Timer interrupt"
[IPMI.notice]: 4403 | 02 | EVT: 6fc104ff | System_Watchdog | Assertion Event, "Hard reset"
[Agent.notice]: 151.570: 52 : NVRAM Destage Request de-asserted
[Agent.notice]: 151.570: 59 : NVRAM 12V Power Good asserted
[Agent.notice]: 450.922: 0 : CPU Power Good from PCH via voltage translation asserted
[Agent.notice]: 451.651: 2 : CPU domain power good (from seq. CPLD) asserted
[Agent.notice]: 513.118: 49 : PCH Platform Reset de-asserted
[SP.critical]: Filer Reboots

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.