DS460c ドロワー障害が原因で複数のディスクがパニック状態になりました

Views:
Visibility:
Public
Votes:
0
Category:
disk-shelves<a>翻訳対象:2009085578</a><a />
Specialty:
hw
Last Updated:

環境

  • DS460c ディスクシェルフ
  • ONTAP 9

問題

  • 1 つのドロワーのドライブがすべてシステムに認識されません
Tue Feb 22 14:46:06 +0000 [node-01: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr_n2_root/plex0/rg0/0a.10.51 Shelf 10 Drawer 5 Slot 3 Bay 51 [NETAPP   X376_WVELE08TA07 NA01] S/N [XXXXXXXX] UID [5000CCA0:C254217C:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
Tue Feb 22 14:46:06 +0000 [node-01: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr2/plex0/rg0/0a.10.48 Shelf 10 Drawer 5 Slot 0 Bay 48 [NETAPP   X376_WVELE08TA07 NA01] S/N [XXXXXXXX] UID [5000CCA0:C2554E84:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
Tue Feb 22 14:46:06 +0000 [node-01: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr2/plex0/rg0/0a.10.49 Shelf 10 Drawer 5 Slot 1 Bay 49 [NETAPP   X376_WVELE08TA07 NA01] S/N [XXXXXXXX] UID [5000CCA0:C25420D4:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
Tue Feb 22 14:46:06 +0000 [node-01: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr2/plex0/rg0/0a.10.50 Shelf 10 Drawer 5 Slot 2 Bay 50 [NETAPP   X376_WVELE08TA07 NA01] S/N [XXXXXXXX] UID [5000CCA0:C25072D4:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
Tue Feb 22 14:46:06 +0000 [node-01: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr2/plex0/rg0/0a.10.52 Shelf 10 Drawer 5 Slot 4 Bay 52 [NETAPP   X376_WVELE08TA07 NA01] S/N [XXXXXXXX] UID [5000CCA0:C2559CB0:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
  • 複数のディスクがパニック状態になったために、 HA ペアの一方または両方のノードがリブートする可能性があります
Tue Feb 22 14:46:06 +0000 [node-01: config_thread: cf.multidisk.fatalProblem:error]: Node encountered a multidisk error or other fatal error while waiting to be taken over. aggr aggr2: raid volfsm, fatal multi-disk error..  Raid type - raid_tec Group name plex0/rg0 state NORMAL. 6 disks failed in the group. Disk /aggr2/plex0/rg0/0a.10.58 Shelf 10 Drawer 5 Slot 10 Bay 58 [NETAPP   X376_WVELE08TA07 NA01] S/N [XXXXXXXX] UID [5000CCA0:C250C3CC:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] error: no valid path to disk. Disk /aggr2/plex0/rg0/0a.10.55 Shelf 10 Drawer 5 Slot 7 Bay 55 [NETAPP   X376_WVELE08TA07 NA01] S/N [XXXXXXXX] UID [5000CCA0:C2559D28:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] error: disk does not exist. Disk 0a.10.48 Shelf 10 Drawer 5 Slot 0 Bay 48 [NETAPP   X376_WVELE08TA07 NA01] S/N [XXXXXXXX] UID [5000CCA0:C2554E84:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] error: no valid path to disk. Disk 0a.10.49 Shelf 10 Drawer 5 Slot 1 Bay 49.
  • sysconfig -a に、シェルフ内の 12 本のドライブが見つからないことが表示されます。  DS460C シェルフには 60 本のドライブ( 0~59 )があります。
    • ドロワー 1 にはドライブ 0~11 が含まれています
    • ドロワー 2 にドライブ 12-23 が搭載されている
    • ドロワー 3 にドライブが 24 ~ 35 本搭載されて
    • ドロワー 4 にドライブ 36-47 が搭載されています
    • ドロワー 5 にはドライブが 48~59 本含まれています
  • sysconfig -a を使用します
10.38: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
10.39: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
10.40: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
10.41: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
10.42: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
10.43: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
10.44: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
10.45: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
10.46: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
10.47: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
<<missing>>
11.0: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)