メインコンテンツまでスキップ

EMS の「 shelf_fault 」が「 SES.status.ACPError : Critical 」と報告されます。

Views:
23
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

のしんだ

に適用されます

  • I/O モジュール( IOM )
  • Alternate Control Path(ACP)
  • サービス プロセッサ(SP)

問題

EMS の「 shelf_fault 」が「 SES.status.ACPError : Critical 」と報告されます。

例:

Sat Mar 19 22:41:51 EST [xxx:ses.status.ACPError:CRITICAL]: DS4246 (S/N XXXXXXXXX) shelf 11 on channel 2c ACP Processor error for SAS shelf ACP processor 2: critical status ; Alternate Control Path hardware failed This module is on the rear of the shelf at the bottom center, on shelf module B. 
Sat Mar 19 22:41:54 EST [xxx:monitor.shelf.fault:CRITICAL]: Fault reported on disk storage shelf attached to channel 1b. Check fans, power supplies, disks, and temperature sensors. 
Sat Mar 19 22:41:54 EST [xxx:callhome.shlf.fault:error]: Call home for SHELF_FAULT 

 

 