メインコンテンツまでスキップ

コントローラの SAS ポートで PHY が無効になっています

Views:
18
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

に適用されます

  • Data ONTAP 8
  • ONTAP 9
  • シリアル接続 SCSI ( SAS )

問題

SAS Port PHY Disabled アラートが「system health alert show」に表示されます。

例:

Clutser1::> system health alert show
               Node: Node1
           Resource: Port 0b
           Severity: Major
    Indication Time: Fri Jan 03 01:07:42 2020
           Suppress: false
        Acknowledge: false
     Probable Cause: SAS port 0b on controller Node1 has 1 disabled
                    PHYs.
    Possible Effect: Inactive PHYs might cause degraded link performance.
Corrective Actions: 1. Verify that SAS port 0b has disabled PHYs by using the "storage port show -node Node1 -port 0b" command.
                     2. If the disk shelves connected to port 0b have multiple path to the node, reset port 0b by using the (privilege: advanced) "storage port reset -node Node1 -port 0b" command.
                     3. Verify that the physical cable connection is secure and operational. If the disk shelves are multipathed, reseat the cable.
                     4. If the connected disk shelf is multipathed, replace
                     the SAS cable.

sysconfig -a」は、 1 つの PHY 状態がディバ状態であることを示します。

例:

slot 0: SAS Host Adapter 0b (PMC-Sierra PM8070 rev. C, SAS, <UP>)
        Firmware rev:       03.08.09.00
        Base WWN:           5:00a098:003abb6:34
        Phy State:         [4] Disabled
                            [5] Enabled, 12.0 Gb/s
                            [6] Enabled, 12.0 Gb/s
                            [7] Enabled, 12.0 Gb/s

 