メインコンテンツまでスキップ

SP 情報が正しく表示されない

Views:
160
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

に適用されます

FAS2650

問題

  • SP のヘルスがデグレードと表示される。
Node03::> system health subsystem show
Subsystem Health
----------------- ------------------
SAS-connect ok
Environment ok
Memory ok
Service-Processor degraded
 
Node03::> system health alert show
 
Node: Node03-02
Resource: SP Config
Severity: Major
Indication Time: Tue Jan 19 09:21:38 2021
Suppress: false
Acknowledge: false
Probable Cause: Service Processor in node Node03-02 has no network
         connectivity.The cable between the Wrench port on the
         controller and the ethernet switch is disconnected.
Possible Effect: You might not be able to use the Service Processor to
         remotely access, monitor, and troubleshoot your
         storage system.
Corrective Actions: 1. Check the connection between the Wrench port and the ethernet switch.
           2. If the cable is properly connected, ensure that the Service Processor's ethernet interface is configured properly by executing the command "system service-processor network show".
           3. Check for network cable related issues.
           4. Contact the technical support if the alert persists.
 
  • ノード node03-02 の情報を表示できません。
 
Node03::> system service-processor show
IP Firmware
Node Type Status Configured Version IP Address
------------- ---- ----------- ------------ --------- -------------------------
Node03-01 SP online true 5.1P1 XXX.XXX.XXX.XXX
 
Error: show failed: RPC: Unable to send
 
Node03::> system service-processor network show
Address
Node Status Family Link State IP Address
------------- -------------- --------- ----------- ------------------------
Node03-01 online IPv4 up XXX.XXX.XXX.XXX
 
DHCP: none
MAC Address: XX:XX:XX:XX:XX:XX
Network Gateway: XXX.XXX.XXX.XXX
Network Mask (IPv4 only): XXX.XXX.XXX.XXX
Prefix Length (IPv6 only): -
IPv6 RA Enabled: -
Subnet Name: -
SP Network Setup Status: succeeded
......
Error: show failed: RPC: Unable to send
2 entries were displayed.
 
  • ただし、 sysconfig -a で、警告 LED が消灯し、 SP のステータスがオンラインになっています
 
Node03::> node run -node * sysconfig -a
Node: Node03-02
NetApp Release 9.1P11: Thu Dec 21 02:32:26 PST 2017
......
Service Processor Status: Online
Firmware Version: 5.1P1
Mgmt MAC Address: XX:XX:XX:XX:XX:XX
Ethernet Link: up, full duplex, auto-neg complete
Using DHCP: no
IPv4 configuration:
IP Address: XXX.XXX.XXX.XXX
Netmask: XXX.XXX.XXX.XXX
Gateway: XXX.XXX.XXX.XXX
IPv6 configuration: Disabled
 
  • SP を再起動しても問題を解決できない。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.