メインコンテンツまでスキップ

スイッチオーバー / スイッチバック中に Solaris FC ホストの接続が切断された

Views:
105
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
san
Last Updated:

環境

  • FC
  • ONTAP 9
  • MetroCluster
  • Solaris

問題

スイッチオーバー / スイッチバックの実行中に FC ホストの接続が切断された

  • ホスト・メッセージ( Solaris ):

Apr 24 10:05:31 Solaris fctl: [ID 517869 kern.warning] WARNING: fp(0)::N_x Port with D_ID=12602, PWWN=200700a098680a8c reappeared in fabric

Apr 24 10:05:31 Solaris fctl: [ID 517869 kern.warning] WARNING: fp(2)::N_x Port with D_ID=22602, PWWN=200500a098680a8c reappeared in fabric

Apr 24 10:05:32 Solaris genunix: [ID 483743 kern.info] /scsi_vhci/disk@g600a09803830357452244c2d45734162 (sd23) multipath status: failed: path 32 fp2/disk@w200500a098680a8c,4 is offline
Apr 24 10:05:32 Solaris genunix: [ID 408114 kern.info] /scsi_vhci/disk@g600a09803830357452244c2d45734159 (sd24) offline
Apr 24 10:05:41 Solaris fmd: [ID 377184 daemon.error] SUNW-MSG-ID: ZFS-8000-FD, TYPE: Fault, VER: 1, SEVERITY: Major

  • NetApp EMS にイニシエータがログインしていることが示されます。

Fri Apr 24 10:05:31 CEST [NetApp_N1: fct_tpd_work_thread_0: scsitarget.fct.portLogin:notice]: Login at target FC port: '3b' by initiator port: '21:00:00:24:ff:3e:be:27' address 0x20d00. The target virtual port is: 'NetApp FC Target Port (8324) FC_01-mc:MCC_LIF_02'.

  • igroup が空です。

::> igroup show -vserver svm_mcc -igroup FC-mcc
      Vserver Name: svm_mcc
      Igroup Name: FC-mcc
        Protocol: fcp
        OS Type: solaris
Portset Binding Igroup: -
      Igroup UUID: 659941e0-d591-11ea-8555-005056a4dc7a
          ALUA: true
       Initiators: -

  • DR 設定が AutoSupport に失敗しました

Fri Apr 24 11:44:34 CEST [NetApp_N1: crs: callhome.dr.apply.failed:error]: Call home for DR CONFIG REPLICATION FAILED

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.