In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

スイッチオーバー / スイッチバック中に Solaris FC ホストの接続が切断された

Views:
40
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
san
Last Updated:

環境

  • FC
  • ONTAP 9
  • MetroCluster
  • Solaris

問題

スイッチオーバー / スイッチバックの実行中に FC ホストの接続が切断された

  • ホスト・メッセージ( Solaris ):

Apr 24 10:05:31 Solaris fctl: [ID 517869 kern.warning] WARNING: fp(0)::N_x Port with D_ID=12602, PWWN=200700a098680a8c reappeared in fabric

Apr 24 10:05:31 Solaris fctl: [ID 517869 kern.warning] WARNING: fp(2)::N_x Port with D_ID=22602, PWWN=200500a098680a8c reappeared in fabric

Apr 24 10:05:32 Solaris genunix: [ID 483743 kern.info] /scsi_vhci/disk@g600a09803830357452244c2d45734162 (sd23) multipath status: failed: path 32 fp2/disk@w200500a098680a8c,4 is offline
Apr 24 10:05:32 Solaris genunix: [ID 408114 kern.info] /scsi_vhci/disk@g600a09803830357452244c2d45734159 (sd24) offline
Apr 24 10:05:41 Solaris fmd: [ID 377184 daemon.error] SUNW-MSG-ID: ZFS-8000-FD, TYPE: Fault, VER: 1, SEVERITY: Major

  • NetApp EMS にイニシエータがログインしていることが示されます。

Fri Apr 24 10:05:31 CEST [NetApp_N1: fct_tpd_work_thread_0: scsitarget.fct.portLogin:notice]: Login at target FC port: '3b' by initiator port: '21:00:00:24:ff:3e:be:27' address 0x20d00. The target virtual port is: 'NetApp FC Target Port (8324) FC_01-mc:MCC_LIF_02'.

  • igroup が空です。

::> igroup show -vserver svm_mcc -igroup FC-mcc
      Vserver Name: svm_mcc
      Igroup Name: FC-mcc
        Protocol: fcp
        OS Type: solaris
Portset Binding Igroup: -
      Igroup UUID: 659941e0-d591-11ea-8555-005056a4dc7a
          ALUA: true
       Initiators: -

  • DR 設定が AutoSupport に失敗しました

Fri Apr 24 11:44:34 CEST [NetApp_N1: crs: callhome.dr.apply.failed:error]: Call home for DR CONFIG REPLICATION FAILED

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support