環境

  • ONTAP 9
  • FAS8300

問題

system health alert show レポート AllPathToOneEndOfStack_Alert

例:

Monitor   node-connect
Alert ID   AllPathToOneEndOfStack_Alert
Alerting Resource   1
Subsystem   SAS-connect
Indication Time   Wed Nov 17 13:29:18 2021
Perceived Severity   Major
AutoSupport Triggered   true
Probable Cause   Cable_tamper
Corrective Actions   
1. Consult the guide applicable to your IOM12 disk shelf to review cabling rules and complete the SAS cabling worksheet for your system.
2. Connect controller CNSENAS07-01 to the first and last disk shelves of stack 1.
3. Verify that controller CNSENAS07-01 is cabled to IOM A and IOM B of stack 1.
4. Contact technical support if the alert persists.
Node ID    Node1
Enable Asup for This Alert   true
Alert Clear Time

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support