メインコンテンツまでスキップ

DS460-12 シェルフ上の複数のディスクが失われたことによるテイクオーバー

Views:
36
Visibility:
Public
Votes:
0
Category:
disk-shelves
Specialty:
hw
Last Updated:

環境

DS460-12ディスク シェルフ

問題

  • システムで計画外のテイクオーバーが発生した場合
  • 監視される EMS メッセージ:

scsi_cmdblk_strthr_admin: scsi.cmd.selectionTimeout:error]: Disk device 0a.02.24: Adapter/target error: HA status 0x7: cdb 0x88:000000014b839560:00000008. Targeted device did not respond to requested I/O. I/O will be retried.

scsi_cmdblk_strthr_admin: scsi.cmd.selectionTimeout:error]: Disk device 0b.02.27: Adapter/target error: HA status 0x7: cdb 0x88:0000000160a47b68:00000008. Targeted device did not respond to requested I/O. I/O will be retried.

scsi_cmdblk_strthr_admin: scsi.cmd.selectionTimeout:error]: Disk device 0a.02.30: Adapter/target error: HA status 0x7: cdb 0x88:000000013ba25ec8:00000008. Targeted device did not respond to requested I/O. I/O will be retried.

scsi_cmdblk_strthr_admin: scsi.cmd.selectionTimeout:error]: Disk device 0a.02.33: Adapter/target error: HA status 0x7: cdb 0x88:0000000123ae7078:00000008. Targeted device did not respond to requested I/O. I/O will be retried.

config_thread: cf.multidisk.fatalProblem:info]: Node encountered a multidisk error or other fatal error while waiting to be taken over. aggr aggr02_SATA_01: raid volfsm, fatal multi-disk error.. Raid type - raid_dp Group name plex0/rg0 state NORMAL. 4 disks failed in the group. Disk 0a.02.24 Shelf 2 Drawer 3 Slot 0 Bay 24 [NETAPP X375_SMBPE04TA07 NA00] S/N [XXXXXXXX] UID [XXXXXXX:XXXXXXX:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] error: disk does not exist. Disk 0a.02.27 Shelf 2 Drawer 3 Slot 3 Bay 27 [NETAPP X375_SMBPE04TA07 NA00] S/N [XXXXXXXX] UID [XXXXXXX:XXXXXXX:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] error: disk does not exist. Disk 0a.02.30 Shelf 2 Drawer 3 Slot 6 Bay 30 [NETAPP X375_WVELE04TA07 NA00] S/N [XXXXXXXX] UID [XXXXXXX:XXXXXXX:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] error: disk does not exist. Disk /aggr02_SATA_01/plex0/rg0/0a.02.33 Shelf 2 Drawer 3 Slot 9 Bay 33.

  • アグリゲートはオフラインのままです。
     Aggregate aggr02_SATA_01 (failed, raid_dp, partial) (block checksums) Plex /aggr02_SATA_01/plex0 (offline, failed, inactive) RAID group /aggr02_SATA_01/plex0/rg0 (partial, block checksums) RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks) --------- ------ ------------- ---- ---- ---- ----- -------------- -------------- dparity 0b.02.0 0b 2 0 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168 parity 0a.02.3 0a 2 3 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168 data 0b.02.6 0b 2 6 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168 data 0a.02.9 0a 2 9 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168 data 0b.02.12 0b 2 12 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168 data 0a.02.15 0a 2 15 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168 data 0b.02.18 0b 2 18 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168 data 0a.02.21 0a 2 21 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168 data FAILED N/A 3807816/ - data FAILED N/A 3807816/ - data FAILED N/A 3807816/ - data FAILED N/A 3807816/ - data 0b.02.36 0b 2 36 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168 data 0a.02.39 0a 2 39 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168 data 0b.02.42 0b 2 42 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168 data 0a.02.45 0a 2 45 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168 data 0b.02.48 0b 2 48 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168 data 0a.02.51 0a 2 51 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168 data 0b.02.54 0b 2 54 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168 Raid group is missing 4 disks.
  • シェルフの電源はオンになっていますが、ドライブが取り付けられているドロワーで LED アクティビティは発生していません。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.