メインコンテンツまでスキップ

BrocadeG610 がファンの障害を報告しています

Views:
2
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

環境

  • Brocade G610
  • MetroCluster Brocade G610 スイッチ

問題

  • Brocade G610 スイッチの内蔵ファンが障害状態になり、自動リカバリします。
  • errdumpログには次のイベントが記録されます。
2021/02/11-14:28:02, [HIL-1206], 586, CHASSIS, ERROR, BrocadeG610, Fan 1 sensor 1 , speed (2649 RPM) below threshold.
2021/02/11-14:28:02, [HIL-1312], 587, CHASSIS, WARNING, BrocadeG610, 1 blower(s) failed. Check all blower units immediately.
2021/02/11-14:28:02, [EM-1034], 588, CHASSIS, ERROR, BrocadeG610, Fan 1 set to faulty, rc=20006.
2021/02/11-14:28:14, [MAPS-1021], 589, FID 128, WARNING, brocade-sw1, RuleName=defCHASSISBAD_FAN_MARG, Condition=CHASSIS(BAD_FAN>=1), Obj:Chassis [ BAD_FAN,1] has contributed to switch status MARGINAL.
2021/02/11-14:28:14, [MAPS-1020], 590, FID 128, WARNING, brocade-sw1, Switch wide status has changed from HEALTHY to MARGINAL.
2021/02/11-14:30:01, [EM-1050], 591, CHASSIS, INFO, BrocadeG610, FRU Fan 1 removal detected.
2021/02/11-14:30:01, [EM-1049], 592, CHASSIS, INFO, BrocadeG610, FRU Fan 1 insertion detected.
2021/02/11-14:30:14, [MAPS-1020], 593, FID 128, WARNING, brocade-sw1, Switch wide status has changed from MARGINAL to HEALTHY.

 