環境

Brocade Fibre Channel ( FC )スイッチ

問題

  • Brocade スイッチが予期せずリブートすることがあります
  • スイッチのログerrdump -a (出力)には、次のような行が表示されることがあります。

2020/06/20-18:01:25, [HAM-1011], 331498, FFDC | CHASSIS, CRITICAL, Brocade300, haReboot is automatically triggered for warm recovery from OOM.
2020/06/20-18:02:42, [HAM-1004], 331505, CHASSIS, INFO, Brocade300, Processor rebooted - Hareboot.