メインコンテンツへスキップ

スイッチ-クラスタのHealth degraded:SFPが存在しないことを報告するパートナースイッチインターフェイス

Views:
3
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
hw
Last Updated:

環境

Cisco NXxxxxクラスタスイッチ

問題

EMSログ
HA Group Notification (Health Monitor process cshm: SwitchIfIslDownWarn_Alert[node02-switch1(FOX000000D2)/Ethernet1/44]) ALERT
 ONTAP CLI
::*> system health alert show Node: node2 Resource: Link Aggregate 10 Alert ID:SwitchIfIslDownWarn_Alert Severity: Major Indication Time: Tue Jun 11 12:26:15 2019 Suppress: false Acknowledge: false Probable Cause: The cable used to connect switch "switch1/ Link Aggregate 10" to the ISL port might be faulty. Possible Effect: Cluster redundancy might be lost. Corrective Actions: 1) Check whether the cable is fully inserted into the interface port on both ends. 2) Reconnect the ISL port using another cable. After reconnecting it, verify whether the link of the ISL port is up by executing the commands as per switch configuration guide or by checking whether the Link status LED is on.
show tech-supportの出力

スイッチ1はインターフェイス1/44のこの情報を提供しました。

interface 1/44 is showing down.
Ethernet1/44 is down (Link not connected)
Ethernet1/44 is down

スイッチ2 はこの情報をインターフェイス1/44に提供しました。

  • show interface transceiver logsセクションのログ
switch2# show interface transceiver
Ethernet1/44
transceiver is not present

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.