メインコンテンツまでスキップ

Brocadeスイッチポートでリンクリセットまたは損失信号エラーが報告されました

Views:
984
Visibility:
Public
Votes:
1
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

環境

Brocadeスイッチ

問題形式

Errdumpレポートの損失信号とリンク障害。

2022/06/26-03:53:42, [MAPS-1003], 42403, SLOT 2 | FID 128, WARNING, FAB1, slot6 port9, U-Port 6/9, Condition=ALL_PORTS(LOSS_SIGNAL/min>3), Current Value:[LOSS_SIGNAL, 386 LOS], RuleName=defALL_PORTSLOSS_SIGNAL_3, Dashboard Category=Port Health.
2022/06/26-03:54:42, [MAPS-1003], 42404, SLOT 2 | FID 128, WARNING, FAB1, slot6 port9, U-Port 6/9, Condition=ALL_PORTS(LOSS_SIGNAL/min>3), Current Value:[LOSS_SIGNAL, 378 LOS], RuleName=defALL_PORTSLOSS_SIGNAL_3, Dashboard Health.

 

2021/10/23-23:38:47, [MAPS-1003], 55690, SLOT 1 | FID 128, WARNING, Fabric1, slot10 port31, U-Port 10/31, Condition=ALL_PORTS(LF/min>3), Current Value:[LF, 4], RuleName=defALL_PORTSLF_3, Dashboard Category=Port Health.
2021/10/23-04:24:46, [PORT-1003], 53615, SLOT 1 | FID 128, WARNING, Fabric1, Port 223 Faulted because of many Link Failures.

2020/04/08-21:35:56, [C3-1014], 2556, CHASSIS, WARNING, Brocade6510,  Link Reset on Port S0,P8(12) vc_no=0 crd(s)lost=12 auto trigger.
2020/04/09-09:03:42, [C3-1014], 2557, CHASSIS, WARNING, Brocade6510,  Link Reset on Port S0,P8(12) vc_no=0 crd(s)lost=12 auto trigger.

  • Porterrshow では、複数のリンク障害が報告されています。

/fabos/cliexec/porterrshow :
      frames    enc   crc   crc   too   too   bad   enc   disc   link   loss   loss   frjt   fbsy  c3timeout   pcs   uncor
    tx    rx    in   err   g_eof  shrt   long   eof    out   c3   fail   sync   sig          tx   rx    err   err

120:   0    0    0    0    0    0    0    0    0    0   62.4k   0    0    0    0    0    0    0    0   

  • コマンドの Brocade TX の RX 電力が 300 uWatts 未満である sfpshow -all

=============
Port  8:
=============
Identifier:  3   SFP
Connector:   7   LC
Transceiver: 7004404000000000 4,8,16_Gbps M5 sw Short_dist
Encoding:   6   64B66B 
Baud Rate:   140  (units 100 megabaud)
Length 9u:   0   (units km)
Length 9u:   0   (units 100 meters)
Length 50u (OM2):  3   (units 10 meters)
Length 50u (OM3):  10   (units 10 meters)
Length 62.5u:0   (units 10 meters)
Length Cu:   0   (units 1 meter)
Vendor Name: BROCADE      
Vendor OUI:  00:05:1e
Vendor PN:   57-0000088-01   
Vendor Rev:  A   
Wavelength:  850  (units nm)
Options:    003a Loss_of_Sig,Tx_Fault,Tx_Disable
BR Max:    0   
BR Min:    0   
Serial No:   HAF6182300004BC 
Date Code:   180605  
DD Type:    0x68
Enh Options: 0xfa
Status/Ctrl: 0x0
Pwr On Time: 1.24 years (10834 hours)
E-Wrap Control: 0
O-Wrap Control: 0
Alarm flags[0,1] = 0x5, 0x40
Warn Flags[0,1] = 0x5, 0x40
Temperature: 55    Centigrade 
Current:    7.506   mAmps 
Voltage:    3314.0  mVolts 
RX Power:   -2.8   dBm (520.8uW) 
TX Power:   -10.3  dBm (92.4  uW) 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support