環境

  • Brocade Fabric OS 7.4以降

問題

  • Brocade スイッチでは、 1 つまたは複数のポートが「ロードレインデバイス」としてマークされ、を実行して確認されます sddquarantine --show

----- SDDQ Data ------
----------------------------------------------------------
Ports marked as Slow Drain Quarantined in the Local Switch:
           2/8
----------------------------------------------------------
Online Quarantined Devices across the fabric
----------------------------------------------------------
Port Index |   PID   |            PWWN
----------------------------------------------------------
     174    | 01ae01 | 00:00:00:00:00:00:00:00
----------------------------------------------------------
Configured Limit=10 Quarantined count in chassis=1

  • errdump -a出力からポイントインタイムを確認することもできます。

2020/06/04-09:25:22, [MAPS-1022], 74058, SLOT 7 | FID 128, WARNING, SANCORESWITCH, Port 2/8 (Port index 24) has been marked as Slow Drain Device.

  • MAPがステートをクリアするまで、ポートステータスは隔離ステートのままになります。

2020/06/04-09:26:22, [MAPS-1003], 74059, SLOT 7 | FID 128, WARNING, SANCORESC10, CASTNASCLP01-03_0e, F-Port 2/8, Condition=ALL_PORTS(DEV_LATENCY_IMPACT==IO_LATENCY_CLEAR), Current Value:[DEV_LATENCY_IMPACT, IO_LATENCY_CLEAR], RuleName=ALL_PORTS_IO_LATENCY_CLEAR, Dashboard Category=Fabric Performance Impact.

2020/06/04-09:36:22, [NS-1018], 74060, SLOT 7 | FID 128, INFO, SANCORESWITCH, Domain 10, Port index 24, All devices zoned with the slow drain device 0x0a1800 have been unquarantined.

2020/06/04-09:36:22, [MAPS-1025], 74062, SLOT 7 | FID 128, WARNING, SANCORESWITCH, Port 2/8 (Port index 24) removed from the Slow Drain Device Quarantine Group

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.